20.8.3 Tomographic Images, Artifact Removal, Enhancement

Chapter Contents (Back)
Enhancement. Artifact Removal. Tomography.

Shepp, L.A., Hilal, S.K., Schulz, R.A.,
The tuning fork artifact in computerized tomography,
CGIP(10), No. 3, July 1979, pp. 246-255.
WWW Version. 0501
BibRef

Herman, G.T.[Gabor T.],
On the noise in images produced by computed tomography,
CGIP(12), No. 3, March 1980, pp. 271-285.
WWW Version. 0501
BibRef

Margosian, P.M.,
Streak Removal Method for CT Based Digital X-Ray Images,
CGIP(19), No. 1, May 1982, pp. 76-80.
WWW Version. BibRef 8205

Lempriere, B.M.[Brian M.],
Method of improving CT resolution,
US_Patent4,907,152, Mar 6, 1990
WWW Version. 2 scans BibRef 9003

Ritchie, C.J., Crawford, C.R., Godwin, J.D., King, K.F., Kim, Y.M.[Yong-Min],
Correction of computed tomography motion artifacts using pixel-specific back-projection,
MedImg(15), No. 3, June 1996, pp. 333-342.
IEEE Top Reference. 0203
BibRef

Hsieh, J.[Jiang],
Three-dimensional artifact induced by projection weighting and misalignment,
MedImg(18), No. 4, April 1999, pp. 364-368.
IEEE Top Reference. 0110
BibRef
And:
Investigation of a 3D Image Artifact Caused by Projection Weighting and Misalignment,
ICIP99(II:681-685).
IEEE Abstract. IEEE Top Reference. BibRef
Earlier:
Impact of helical reconstruction algorithm on 3D image artifacts,
ICIP98(II: 690-694).
IEEE DOI Link 9810
BibRef
Earlier:
Partial volume artifact reduction in computed tomography,
ICIP96(III: 567-570).
IEEE DOI Link 9610
BibRef

Hsieh, J.[Jiang],
Reconstruction Optimization for Temporal Response Improvement in CT Fluoroscopy,
ICIP99(II:672-676).
IEEE Abstract. IEEE Top Reference. BibRef 9900
Earlier:
Improving the Temporal Response of Computed Tomography Fluoroscopy with Optimized Halfscan,
ICIP97(I: 484-487).
IEEE DOI Link BibRef

Schaller, S., Wildberger, J.E., Raupach, R., Niethammer, M., Klingenbeck-Regn, K., Flohr, T.,
Spatial domain filtering for fast modification of the tradeoff between image sharpness and pixel noise in computed tomography,
MedImg(22), No. 7, July 2003, pp. 846-853.
IEEE Abstract. IEEE Top Reference. 0308
BibRef

Villain, N., Goussard, Y., Idier, J., Allain, M.,
Three-dimensional edge-preserving image enhancement for computed tomography,
MedImg(22), No. 10, October 2003, pp. 1275-1287.
IEEE Abstract. IEEE Top Reference. 0310
BibRef

Pan, X., Yu, L., Kao, C.M.,
Spatial-Resolution Enhancement in Computed Tomography,
MedImg(24), No. 2, February 2005, pp. 246-253.
IEEE Abstract. IEEE Top Reference. 0501
BibRef

La Riviere, P.J., Billmire, D.M.,
Reduction of noise-induced streak artifacts in X-ray computed tomography through spline-based penalized-likelihood sinogram smoothing,
MedImg(24), No. 1, January 2005, pp. 105-111.
IEEE Abstract. IEEE Top Reference. 0501
BibRef

La Riviere, P.J., Bian, J., Vargas, P.A.,
Penalized-Likelihood Sinogram Restoration for Computed Tomography,
MedImg(25), No. 8, August 2006, pp. 1022-1036.
IEEE DOI Link 0608
BibRef

La Riviere, P.J., Vargas, P.A.,
Monotonic penalized-likelihood image reconstruction for X-ray fluorescence computed tomography,
MedImg(25), No. 9, September 2006, pp. 1117-1129.
IEEE DOI Link 0609
BibRef

La Riviere, P.J., Vargas, P.A.,
Correction for Resolution Nonuniformities Caused by Anode Angulation in Computed Tomography,
MedImg(27), No. 9, September 2008, pp. 1333-1341.
IEEE DOI Link 0809
BibRef

Wang, J., Li, T., Lu, H., Liang, Z.,
Penalized Weighted Least-Squares Approach to Sinogram Noise Reduction and Image Reconstruction for Low-Dose X-Ray Computed Tomography,
MedImg(25), No. 10, October 2006, pp. 1272-1283.
IEEE DOI Link 0609
BibRef

Zhu, L., Bennett, N.R., Fahrig, R.,
Scatter Correction Method for X-Ray CT Using Primary Modulation: Theory and Preliminary Results,
MedImg(25), No. 12, December 2006, pp. 1573-1587.
IEEE DOI Link 0701
BibRef

Desbat, L., Roux, S., Grangeat, P.,
Compensation of Some Time Dependent Deformations in Tomography,
MedImg(26), No. 2, February 2007, pp. 261-269.
IEEE DOI Link 0702
BibRef

Gravier, E.[Erwan], Yang, Y.Y.[Yong-Yi], Jin, M.[Mingwu],
Tomographic Reconstruction of Dynamic Cardiac Image Sequences,
IP(16), No. 4, April 2007, pp. 932-942.
IEEE DOI Link 0704
BibRef
Earlier: A1, A2, Only:
Motion-compensated reconstruction of tomographic image sequences,
ICIP03(II: 807-810).
IEEE Abstract. IEEE Top Reference. 0312
BibRef

Salinas, H.M., Fernandez, D.C.,
Comparison of PDE-Based Nonlinear Diffusion Approaches for Image Enhancement and Denoising in Optical Coherence Tomography,
MedImg(26), No. 6, June 2007, pp. 761-771.
IEEE DOI Link 0706
BibRef

Arivazhagan, S., Deivalakshmi, S., Kannan, K., Gajbhiye, B.N., Muralidhar, C., Lukose, S.N.[Sijo N.], Subramanian, M.P.,
Multi-resolution system for artifact removal and edge enhancement in computerized tomography images,
PRL(28), No. 13, 1 October 2007, pp. 1769-1780.
WWW Version. 0709
Industrial CT images; Edge enhancement; Multi-resolution techniques BibRef

Schaap, M., Schilham, A.M.R., Zuiderveld, K.J., Prokop, M., Vonken, E.J., Niessen, W.J.,
Fast Noise Reduction in Computed Tomography for Improved 3-D Visualization,
MedImg(27), No. 8, August 2008, pp. 1120-1129.
IEEE DOI Link 0808
BibRef

Liu, Y.H.[Yi-Heng], Liang, Y.M.[Yan-Mei], Mu, G.G.[Guo-Guang], Zhu, X.N.[Xiao-Nong],
Deconvolution methods for image deblurring in optical coherence tomography,
JOSA-A(26), No. 1, January 2009, pp. 72-77.
WWW Version. 0804
BibRef

Lemmens, C., Faul, D., Nuyts, J.,
Suppression of Metal Artifacts in CT Using a Reconstruction Procedure That Combines MAP and Projection Completion,
MedImg(28), No. 2, February 2009, pp. 250-260.
IEEE DOI Link 0902
BibRef

Mendrik, A.M.[Adriënne M.], Vonken, E.J., Rutten, A., Viergever, M.A., van Ginneken, B.,
Noise Reduction in Computed Tomography Scans Using 3-D Anisotropic Hybrid Diffusion With Continuous Switch,
MedImg(28), No. 10, October 2009, pp. 1585-1594.
IEEE DOI Link 0910
BibRef


Chandra, S.[Shekhar], Svalbe, I.[Imants],
A method for removing cyclic artefacts in discrete tomography using latin squares,
ICPR08(1-4).
IEEE DOI Link 0812
BibRef

Axelsson, M.[Maria], Svensson, S.[Stina], Borgefors, G.[Gunilla],
Reduction of Ring Artifacts in High Resolution X-Ray Microtomography Images,
DAGM06(61-70).
Springer DOI Link 0610
BibRef

Yuasa, T., Devaraj, B., Tanosaki, S., Taniguchi, H., Akatsuka, T.,
Reconstruction Method for Compensation of Surface Effects in Transillumination Laser CT,
ICIP01(I: 341-344).
IEEE Abstract. IEEE Top Reference. 0108
BibRef

Hassanien, A.E., Karam, H., Akter, H., Nakajima, M.,
Generation of Missing Medical Slices Using Morphing Technology,
MVA98(xx-yy). BibRef 9800

Garren, D.A., Goldstein, J.S.,
Extraction of multiple-bounce artifacts in tomographic imaging,
ICIP02(II: 613-616).
IEEE Abstract. IEEE Top Reference. 0210
BibRef

Kazantsev, I.G.[Ivan G.],
Tomographic artefacts suppression via backprojection operator optimization,
ICIP96(I: 749-751).
IEEE DOI Link 9610
BibRef

Chapter on Medical Applications, CAT, MRI, Ultrasound, Heart Models, Brain Models continues in
Electrical Impedance Tomography .


Last update:Nov 16, 2009 at 19:35:14