Tsuji, S.[Saburo],
Osada, M., and
Yachida, M.[Masahiko],
Tracking and Segmentation of Moving Objects in Dynamic Line Images,
PAMI(2), No. 6, November 1980, pp. 516-522.
BibRef
8011
Earlier:
Three Dimensional Movement Analysis of Dynamic Line Images,
IJCAI79(896-901).
Matching, Contours.
Snakes. Flexible template match with corresponding segments, group by
similarity of motion of the segments.
BibRef
Yachida, M.[Masahiko],
Ikeda, M.[Motozo], and
Tsuji, S.[Saburo],
A Plan-Guided Analysis of Cineangiograms for Measurement of
Dynamic Behavior of Heart Wall,
PAMI(2), No. 6, November 1980, pp. 537-543.
BibRef
8011
Earlier:
Plan Guided Analysis of Noisy Dynamic Images,
IJCAI79(978-983).
BibRef
Cavouras, D.,
Wayne, L.N.[L. Norton],
Tomographic mapping of the activity of the heart wall,
PR(14), No. 1-6, 1981, pp. 17-32.
WWW Version.
0309
BibRef
Bunke, H.,
Sagerer, G.,
Niemann, H.,
Model Based Analysis of Scintigraphic Image Sequences of the
Human Heart,
ISPDSA83(725-740).
BibRef
8300
Gerbrands, J.J.,
Slump, C.H.,
3-D Reconstruction of Homogeneous Objects from two
Poisson-Distributed Projections,
PRL(3), 1985, pp. 137-145.
BibRef
8500
Slump, C.H.,
Gerbrands, J.J.,
A Network Flow Approach to Reconstruction of the
Left Ventricle from Two Projections,
CGIP(18), No. 1, January 1982, pp. 18-36.
WWW Version.
BibRef
8201
Ritchings, R.T.,
Colchester, A.C.F.,
Wang, H.Q.,
Knowledge-Based Analysis of Carotid Angiograms,
IVC(3), No. 4, November 1985, pp. 217-222.
WWW Version.
BibRef
8511
Acharya, R.S.,
Heffernan, P.,
Robb, R.A.,
High-Speed 3D Imaging of the Beating Heart Using Temporal Estimation,
CVGIP(39), No. 3, September 1987, pp. 279-290.
BibRef
8709
Chou, W.S.[Wen-Shou],
Wu, C.M.[Chung-Ming],
Chen, Y.C.[Yung-Chang],
Hsieh, K.S.[Kai-Sheng],
Detecting myocardial boundaries of left ventricle from a single frame
2DE image,
PR(23), No. 7, 1990, pp. 799-806.
WWW Version.
0401
BibRef
Tsai, C.T.[Ching-Tsorng],
Sun, Y.N.[Yung-Nien],
Chung, P.C.[Pau-Choo],
Lee, J.S.[Jiann-Shu],
Endocardial boundary detection using a neural network,
PR(26), No. 7, July 1993, pp. 1057-1068.
WWW Version.
0401
BibRef
Baroni, M.[Maurizio],
Barletta, G.[Giuseppe],
Digital curvature estimation for left ventricular shape analysis,
IVC(10), No. 7, September 1992, pp. 485-494.
WWW Version.
0401
BibRef
Solaiyappan, M.,
Poston, T.,
Heng, P.A.,
McVeigh, E.R.,
Guttman, M.A.,
Zerhouni, E.A.,
Interactive Visualization for Rapid Noninvasive Cardiac Assessment,
Computer(29), No. 1, January 1996, pp. 55-62.
BibRef
9601
Prause, G.P.M.,
Onnasch, D.G.W.,
Binary reconstruction of the heart chambers from biplane angiographic
image sequences,
MedImg(15), No. 4, August 1996, pp. 532-546.
IEEE Top Reference.
0203
BibRef
Wang, H.Q.,
Ritchings, R.T.,
Image Understanding System for Carotid Angiograms,
IVC(5), No. 2, May 1987, pp. 79-83.
WWW Version.
BibRef
8705
Ritchings, R.T.,
Colchester, A.C.F.,
Detection of Abnormalities on Carotid Angiograms
Using Syntactic Techniques,
PRL(4), 1986, pp. 367-374.
BibRef
8600
Higgins, W.E.,
Spyra, W.J.T.,
Karwoski, R.A.,
Ritman, E.L.[Erik L.],
System for analyzing high-resolution three-dimensional coronary
angiograms,
MedImg(15), No. 3, June 1996, pp. 377-385.
IEEE Top Reference.
0203
BibRef
Ho, B.K.T.,
Tsai, M.J.[Min-Jen],
Wei, J.[Jun],
Ma, M.,
Saipetch, P.,
Video compression of coronary angiograms based on discrete wavelet
transform with block classification,
MedImg(15), No. 6, December 1996, pp. 814-823.
IEEE Top Reference.
0203
BibRef
Ezquerra, N.,
Capell, S.,
Klein, L.,
Duijves, P.,
Model-Guided Labeling of Coronary Structure,
MedImg(17), No. 3, June 1998, pp. 429-441.
IEEE Top Reference.
9809
BibRef
Nalcioglu, O.,
Roeck, W.W.,
Reese, T.,
Qu, L.Z.,
Tobis, J.M.,
Henry, W.L.,
Background subtraction algorithms for videodensitometric quantification
of coronary stenosis,
MVA(1), No. 3, 1988, pp. 155-162.
BibRef
8800
Suri, J.S.[Jasjit S.],
Computer Vision, Pattern Recognition and Image Processing in Left
Ventricle Segmentation: The Last 50 Years,
PAA(3), No. 3 2000, pp. 209-242.
0010
Survey, Segmentation.
BibRef
Bonciu, C.,
Weber, R.,
Léger, C.,
4D reconstruction of the left ventricle during a single heart beat from
ultrasound imaging,
IVC(19), No. 6, April 2001, pp. 401-412.
WWW Version.
0105
BibRef
Setarehdan, S.K., and
Soraghan, J.J.,
Automatic cardiac LV boundary detection and tracking using
hybrid fuzzy temporal and fuzzy multiscale edge detection,
BiomedEng(46), No. 11, November 1999, pp. 1364-1378.
BibRef
9911
Sheikh Akbari, A.,
Soraghan, J.J.,
Fuzzy-Based Multiscale Edge Detection,
IEE-P(Electronics Letters 39), No. 1, 2003, pp. 30-32.
BibRef
0300
Sheikh Akbari, A.,
Soraghan, J.J.,
Multiscale fuzzy reasoning (MFR) for automatic object extraction,
PRL(26), No. 1, 1 January 2005, pp. 77-81.
WWW Version.
0501
BibRef
Narayanan, M.V.,
King, M.A.,
Wernick, M.N.,
Byrne, C.L.,
Soares, E.J.,
Pretorius, P.H.,
Improved image quality and computation reduction in 4-D reconstruction
of cardiac-gated SPECT images,
MedImg(19), No. 5, May 2000, pp. 423-433.
IEEE Top Reference.
0110
BibRef
Jin, M.[Mingwu],
Yang, Y.Y.[Yong-Yi],
Wernick, M.N.,
Reconstruction of Cardiac-Gated Dynamic SPECT Images,
ICIP05(III: 752-755).
WWW Version.
0512
BibRef
Frangi, A.F.,
Niessen, W.J.,
Viergever, M.A.,
Three-dimensional modeling for functional analysis of cardiac images:
A Review,
MedImg(20), No. 1, January 2001, pp. 2-5.
IEEE Top Reference.
0110
BibRef
Frangi, A.F.,
Rueckert, D.,
Schnabel, J.A.,
Niessen, W.J.,
Automatic construction of multiple-object three-dimensional statistical
shape models: application to cardiac modeling,
MedImg(21), No. 9, September 2002, pp. 1151-1166.
IEEE Top Reference.
0301
See also Automatic construction of 3-D statistical deformation models of the brain using nonrigid registration.
BibRef
Rogowska, J.,
Brezinski, M.E.,
Evaluation of the adaptive speckle suppression filter for coronary
optical coherence tomography imaging,
MedImg(19), No. 12, December 2000, pp. 1261-1266.
IEEE Top Reference.
0110
BibRef
Sui, L.[Lei],
Haralick, R.M.[Robert M.],
Sheehan, F.H.[Florence H.],
A Knowledge-Based Boundary Delineation System for
Contrast Ventriculograms,
ITBio(5), No. 2, June 2001, pp. 116-132.
BibRef
0106
Suri, J.S.[Jasjit S.],
Haralick, R.M.[Robert M.],
Sheehan, F.H.[Florence H.],
Automatic Quadratic Calibration for Correction of
Pixel Classifier Boundaries to an Accuracy of 2.5mm:
An Application in X-ray Heart Imaging,
ICPR98(Vol I: 30-33).
WWW Version.
9808
BibRef
Earlier:
Left Ventricle Longitudinal Axis Fitting and its Apex Estimation Using A
Robust Algorithm and its Performance: A Parametric Apex Model,
ICIP97(III: 118-121).
WWW Version.
BibRef
Debreuve, É.[Éric],
Barlaud, M.[Michel],
Aubert, G.[Gilles],
Laurette, I.,
Darcourt, J.,
Space-time segmentation using level set active contours applied to
myocardial gated SPECT,
MedImg(20), No. 7, July 2001, pp. 643-659.
IEEE Top Reference.
0110
BibRef
Amadieu, O.[Olivier],
Debreuve, E.[Eric],
Barlaud, M.[Michel],
Aubert, G.[Gilles],
Inward and Outward Curve Evolution Using Level Set Method,
ICIP99(III:188-192).
IEEE Abstract. IEEE Top Reference.
BibRef
9900
Talukdar, A.S.,
Wilson, D.L.,
Modeling and optimization of rotational C-arm stereoscopic X-ray
angiography,
MedImg(18), No. 7, July 1999, pp. 604-616.
IEEE Top Reference.
0110
BibRef
Ning, R.[Ruola],
Chen, B.[Biao],
Yu, R.F.[Rong-Feng],
Conover, D.,
Tang, X.Y.[Xiang-Yang],
Ning, Y.[Yi],
Flat panel detector-based cone-beam volume CT angiography imaging:
system evaluation,
MedImg(19), No. 9, September 2000, pp. 949-963.
IEEE Top Reference.
0110
BibRef
Kump, K.S.,
Saidel, G.M.,
Wilson, D.L.,
Comparison of algorithms for combining X-ray angiography images,
MedImg(20), No. 8, August 2001, pp. 742-750.
IEEE Top Reference.
0110
BibRef
Jani, A.B.,
Pelizzari, C.A.,
Chen, G.T.Y.,
Roeske, J.,
Hamilton, R.J.,
MacDonald, R.L.,
Bova, F.,
Hoffmann, K.R.,
Sweeney, P.A.,
Volume rendering quantification algorithm for reconstruction of CT
volume-rendered structures. 1. Cerebral arteriovenous malformations,
MedImg(19), No. 1, January 2000, pp. 12-24.
IEEE Top Reference.
0110
BibRef
Close, R.A.,
Abbey, C.K.,
Morioka, C.A.,
Whiting, J.S.,
Accuracy assessment of layer decomposition using simulated angiographic
image sequences,
MedImg(20), No. 10, October 2001, pp. 990-998.
IEEE Top Reference.
0111
BibRef
Behloul, F.,
Lelieveldt, B.P.F.,
Boudraa, A.,
Janier, M.F.,
Revel, D.,
Reiber, J.H.C.,
Neuro-fuzzy systems for computer-aided myocardial viability assessment,
MedImg(20), No. 12, December 2001, pp. 1302-1313.
IEEE Top Reference.
0201
BibRef
Hoetink, A.E.,
Faes, T.J.C.,
Marcus, J.T.,
Kerkkamp, H.J.J.,
Heethaar, R.M.,
Imaging of thoracic blood volume changes during the heart cycle with
electrical impedance using a linear spot-electrode array,
MedImg(21), No. 6, June 2002, pp. 653-661.
IEEE Top Reference.
0208
BibRef
Semenov, S.Y.,
Svenson, R.H.,
Posukh, V.G.,
Nazarov, A.G.,
Sizov, Y.E.,
Bulyshev, A.E.,
Souvorov, A.E.,
Chen, W.,
Kasell, J.,
Tatsis, G.P.,
Dielectrical spectroscopy of canine myocardium during acute ischemia
and hypoxia at frequency spectrum from 100 khz to 6 ghz,
MedImg(21), No. 6, June 2002, pp. 703-707.
IEEE Top Reference.
0208
BibRef
Moriyama, M.,
Sato, Y.,
Naito, H.,
Hanayama, M.,
Ueguchi, T.,
Harada, T.,
Yoshimoto, F.,
Tamura, S.,
Reconstruction of time-varying 3-d left-ventricular shape from
multiview x-ray cineangiocardiograms,
MedImg(21), No. 7, July 2002, pp. 773-785.
IEEE Top Reference.
0210
BibRef
Canero, C.,
Vilarino, F.,
Mauri, J.,
Radeva, P.I.,
Predictive (un)distortion model and 3-D reconstruction by biplane
snakes,
MedImg(21), No. 9, September 2002, pp. 1188-1201.
IEEE Top Reference.
0301
BibRef
Gil, D.,
Hernandez, A.,
Rodriguez, O.,
Mauri, J.,
Radeva, P.I.,
Statistical Strategy for Anisotropic Adventitia Modelling in IVUS,
MedImg(25), No. 6, June 2006, pp. 768-778.
WWW Version.
0606
BibRef
Gil, D.,
Rodriguez-Leor, O.,
Radeva, P.I.,
Mauri, J.,
Myocardial Perfusion Characterization From Contrast Angiography
Spectral Distribution,
MedImg(27), No. 5, May 2008, pp. 641-649.
WWW Version.
0711
BibRef
Makela, T.,
Clarysse, P.,
Sipila, O.,
Pauna, N.,
Pham, Q.C.[Quoc Cuong],
Katila, T.,
Magnin, I.E.,
A review of cardiac image registration methods,
MedImg(21), No. 9, September 2002, pp. 1011-1021.
IEEE Top Reference.
0301
BibRef
Tilg, B.,
Fischer, G.,
Modre, R.,
Hanser, F.,
Messnarz, B.,
Schocke, M.,
Kremser, C.,
Berger, T.,
Hintringer, F.,
Roithinger, F.X.,
Model-based imaging of cardiac electrical excitation in humans,
MedImg(21), No. 9, September 2002, pp. 1031-1039.
IEEE Top Reference.
0301
BibRef
Frangl, A.F.,
Rueckert, D.,
Duncan, J.S.,
Three-dimensional cardiovascular image analysis,
MedImg(21), No. 9, September 2002, pp. 1005-1010.
IEEE Top Reference.
0301
BibRef
Sheehan, F.H.,
Bolson, E.L.,
McDonald, J.A.,
Reisman, M.,
Koch, K.,
Poppas, A.,
Method for three-dimensional data registration from disparate imaging
modalities in the NOGA myocardial viability trial,
MedImg(21), No. 10, October 2002, pp. 1264-1270.
IEEE Top Reference.
0301
BibRef
Nguyen, T.D.,
Reeves, S.J.,
Denney, Jr., T.S.,
On the optimality of magnetic resonance tag patterns for heart wall
motion estimation,
IP(12), No. 5, May 2003, pp. 524-532.
WWW Version.
0307
BibRef
Earlier:
New magnetic resonance tagging technique for directly measuring the
strain tensor of the in vivo human heart,
ICIP98(I: 694-698).
WWW Version.
9810
BibRef
Denney, Jr., T.S.,
Prince, J.L.,
Lopez, M.J.,
McVeigh, E.R.,
Optimal tag pattern validation using magnetic resonance imaging,
ICIP94(I: 881-885).
WWW Version.
9411
BibRef
Yan, L.[Litao],
Denney, Jr., T.S.,
Unsupervised estimation of left ventricular displacement from MR tagged
images using Markov random field edge priors,
ICIP98(I: 689-693).
WWW Version.
9810
BibRef
Ghanem, R.N.,
Ramanathan, C.,
Jia, P.[Ping],
Rudy, Y.,
Heart-surface reconstruction and ECG electrodes localization using
fluoroscopy, epipolar geometry and stereovision: application to
noninvasive imaging of cardiac electrical activity,
MedImg(22), No. 10, October 2003, pp. 1307-1318.
IEEE Abstract. IEEE Top Reference.
0310
BibRef
Sornborger, A.,
Sirovich, L.,
Morley, G.,
Extraction of periodic multivariate signals: mapping of
voltage-dependentdye fluorescence in the mouse heart,
MedImg(22), No. 12, December 2003, pp. 1537-1549.
IEEE Abstract. IEEE Top Reference.
0401
BibRef
Piliouras, N.,
Kalatzis, I.,
Theocharakis, P.,
Dimitropoulos, N.,
Cavouras, D.,
Development of the probabilistic neural network-cubic least squares
mapping (PNN-LSM3) classifier to assess carotid plaque's risk,
PRL(25), No. 2, January 2004, pp. 249-258.
WWW Version.
0401
BibRef
Suzuki, K.,
Horiba, I.,
Sugie, N.,
Nanki, M.,
Extraction of Left Ventricular Contours From Left Ventriculograms by
Means of a Neural Edge Detector,
MedImg(23), No. 3, March 2004, pp. 330-339.
IEEE Abstract. IEEE Top Reference.
0403
BibRef
Medina, R.,
Garreau, M.,
Toro, J.,
Coatrieux, J.L.,
Jugo, D.,
Three-Dimensional Reconstruction of the Left Ventricle From Two
Angiographic Views: An Evidence Combination Approach,
SMC-A(34), No. 3, May 2004, pp. 359-370.
IEEE Abstract. IEEE Top Reference.
0404
BibRef
Medina, R.,
Garreau, M.,
Toro, J.,
Breton, H.L.,
Coatrieux, J.L.,
Jugo, D.,
Markov Random Field Modeling for Three-Dimensional Reconstruction of
the Left Ventricle in Cardiac Angiography,
MedImg(25), No. 8, August 2006, pp. 1087-1100.
WWW Version.
0608
BibRef
Brusseau, E.,
de Korte, C.L.,
Mastik, F.,
Schaar, J.,
van der Steen, A.F.W.,
Fully automatic luminal contour segmentation in intracoronary
ultrasound imaging-a statistical approach,
MedImg(23), No. 5, May 2004, pp. 554-566.
IEEE Abstract. IEEE Top Reference.
0406
BibRef
Zhang, Y.N.[Ya-Ni],
Pham, B.T.,
Eckstein, M.P.,
Automated optimization of JPEG 2000 encoder options based on model
observer performance for detecting variable signals in X-ray coronary
angiograms,
MedImg(23), No. 4, April 2004, pp. 459-474.
IEEE Abstract. IEEE Top Reference.
0406
BibRef
Zhang, Y.N.[Ya-Ni],
Pham, B.T.,
Eckstein, M.P.,
Evaluation of JPEG 2000 encoder options: human and model observer
detection of variable signals in X-ray coronary angiograms,
MedImg(23), No. 5, May 2004, pp. 613-632.
IEEE Abstract. IEEE Top Reference.
0406
BibRef
Zhang, Y.N.[Ya-Ni],
Pham, B.T.,
Eckstein, M.P.,
The Effect of Nonlinear Human Visual System Components on Performance
of a Channelized Hotelling Observer in Structured Backgrounds,
MedImg(25), No. 10, October 2006, pp. 1348-1362.
WWW Version.
0609
BibRef
Remme, E.W.,
Augenstein, K.F.,
Young, A.A.,
Hunter, P.J.,
Parameter Distribution Models for Estimation of Population Based Left
Ventricular Deformation Using Sparse Fiducial Markers,
MedImg(24), No. 3, March 2005, pp. 381-388.
IEEE Abstract. IEEE Top Reference.
0501
BibRef
Himel, IV, H.D.,
Knisley, S.B.,
Imaging of Cardiac Movement Using Ratiometric and Nonratiometric
Optical Mapping: Effects of Ischemia and 2, 3-Butaneodione Monoxime,
MedImg(25), No. 1, January 2006, pp. 122-127.
WWW Version.
0601
BibRef
Kim, D.Y.[Do Yeon],
Park, J.W.[Jong Won],
Connectivity-based local adaptive thresholding for carotid artery
segmentation using MRA images,
IVC(23), No. 14, 12 December 2005, pp. 1277-1287.
WWW Version.
0601
BibRef
Sermesant, M.,
Delingette, H.,
Ayache, N.,
An Electromechanical Model of the Heart for Image Analysis and
Simulation,
MedImg(25), No. 5, May 2006, pp. 612-625.
WWW Version.
0605
BibRef
Lauritsch, G.,
Boese, J.,
Wigstrom, L.,
Kemeth, H.,
Fahrig, R.,
Towards Cardiac C-Arm Computed Tomography,
MedImg(25), No. 7, July 2006, pp. 922-934.
WWW Version.
0606
BibRef
Schafer, D.,
Borgert, J.,
Rasche, V.,
Grass, M.,
Motion-Compensated and Gated Cone Beam Filtered Back-Projection for 3-D
Rotational X-Ray Angiography,
MedImg(25), No. 7, July 2006, pp. 898-906.
WWW Version.
0606
BibRef
Polat, K.[Kemal],
Günes, S.[Salih],
Tosun, S.[Sülayman],
Diagnosis of heart disease using artificial immune recognition system
and fuzzy weighted pre-processing,
PR(39), No. 11, November 2006, pp. 2186-2193.
WWW Version.
0608Heart disease; Artificial immune system; AIRS;
Fuzzy weighted pre-processing; k-fold cross validation; Medical diagnosis
BibRef
Oost, E.,
Koning, G.,
Sonka, M.,
Oemrawsingh, P.V.,
Reiber, J.H.C.,
Lelieveldt, B.P.F.,
Automated contour detection in X-ray left ventricular angiograms using
multiview active appearance models and dynamic programming,
MedImg(25), No. 9, September 2006, pp. 1158-1171.
WWW Version.
0609
BibRef
Dehmeshki, J.,
Ye, X.,
Amin, H.,
Abaei, M.,
Lin, X.,
Qanadli, S.D.,
Volumetric Quantification of Atherosclerotic Plaque in CT Considering
Partial Volume Effect,
MedImg(26), No. 3, March 2007, pp. 273-282.
WWW Version.
0703
BibRef
Liu, H.F.[Hua-Feng],
Shi, P.C.[Peng-Cheng],
State-Space Analysis of Cardiac Motion With Biomechanical Constraints,
IP(16), No. 4, April 2007, pp. 901-917.
WWW Version.
0704
BibRef
Wong, K.,
Liu, H.F.[Hua-Feng],
Sinusas, A.J.[Albert J.],
Shi, P.C.[Peng-Cheng],
Multiframe nonrigid motion analysis with anisotropic spatial
constraints: applications to cardiac image analysis,
ICIP04(I: 131-134).
WWW Version.
0505
BibRef
Tong, S.[Shan],
Sinusas, A.J.[Albert J.],
Shi, P.C.[Peng-Cheng],
Sampled-Data H- Filtering for Robust Kinematics Estimation:
Applications to Biomechanics-Based Cardiac Image Analysis,
ICIP06(2525-2528).
0610
WWW Version.
BibRef
And:
Continuous-Discrete Filtering for Cardiac Kinematics Estimation under
Spatio-Temporal Biomechanical Constrains,
ICPR06(I: 167-170).
WWW Version.
0609
BibRef
Sang, N.[Nong],
Li, H.[Heng],
Peng, W.X.[Wei-Xue],
Zhang, T.X.[Tian-Xu],
Knowledge-based adaptive thresholding segmentation of digital
subtraction angiography images,
IVC(25), No. 8, 1 August 2007, pp. 1263-1270.
WWW Version.
0706Digital subtraction angiography; Adaptive threshold; The busyness
BibRef
Bharkhada, D.[Deepak],
Yu, H.Y.[Heng-Yong],
Zeng, K.[Kai],
Bai, E.W.[Er-Wei],
Wang, G.[Ge],
A comparative study on interpolation methods for controlled cardiac CT,
IJIST(17), No. 2, 2007, pp. 91-98.
WWW Version.
0710
BibRef
Kroon, W.[Wilco],
Delhaas, T.[Tammo],
Arts, T.[Theo],
Bovendeerd, P.[Peter],
Constitutive Modeling of Cardiac Tissue Growth,
FIMH07(340-349).
WWW Version.
0706
BibRef
Gilbert, S.H.[Stephen H.],
Benson, A.P.[Alan P.],
Li, P.[Pan],
Holden, A.V.[Arun V.],
Visualisation of Dog Myocardial Structure from Diffusion Tensor
Magnetic Resonance Imaging: The Paradox of Uniformity and Variability,
FIMH07(403-412).
WWW Version.
0706
BibRef
Kumar, D.[Dinesh],
Shen, D.G.[Ding-Gang],
Wei, L.[Liyang],
Turlapthi, R.[Ram],
Suri, J.S.[Jasjit S.],
Motion Correction Strategies for Interventional Angiography Images:
A Comparative Approach,
ICIP07(I: 497-500).
WWW Version.
0709
BibRef
Bravo, A.[Antonio],
Medina, R.[Rubén],
Díaz, J.A.[J. Arelis],
A Clustering Based Approach for Automatic Image Segmentation:
An Application to Biplane Ventriculograms,
CIARP06(316-325).
WWW Version.
0611
BibRef
Chan, M.Y.[Ming-Yuen],
Qu, H.[Huamin],
Wu, Y.C.[Ying-Cai],
Zhou, H.[Hong],
Viewpoint Selection for Angiographic Volume,
ISVC06(I: 528-537).
WWW Version.
0611
BibRef
Condurache, A.P.,
Aach, T.,
Kaiser, A.,
Radke, P.,
User-defined ROI tracking for estimation of the myocardial blush grade,
Southwest06(66-70).
WWW Version.
0603
BibRef
Yu, G.[Gang],
Wang, C.G.[Chang-Guo],
Li, P.[Peng],
Miao, Y.[Yalin],
Bian, Z.[Zhengzhong],
A Statistical Level Set Framework for Segmentation of Left Ventricle,
IWICPAS06(396-405).
WWW Version.
0608
BibRef
Rocha, R.[Rui],
Campilho, A.[Aurélio],
Silva, J.[Jorge],
Segmentation of Ultrasonic Images of the Carotid,
ICIAR05(949-957).
WWW Version.
0509
BibRef
Xue, X.[Xinwei],
Interactive 3D Heart Chamber Partitioning with a New Marker-Controlled
Watershed Algorithm,
ISVC05(92-99).
WWW Version.
0512
BibRef
Noble, J.A.[J. Alison],
Cardiology Meets Image Analysis: Just an Application or Can Image
Analysis Usefully Impact Cardiology Practice?,
CVBIA05(25-30).
WWW Version.
0601
BibRef
Zhuang, L.[Ling],
Liu, H.F.[Hua-Feng],
Chen, W.[Wei],
Bao, H.J.[Hu-Jun],
Shi, P.C.[Peng-Cheng],
Simultaneous Segmentation and Motion Recovery in 3D Cardiac Image
Analysis,
CVBIA05(499-507).
WWW Version.
0601
BibRef
Florin, C.[Charles],
Williams, J.[James],
Khamene, A.[Ali],
Paragios, N.[Nikos],
Registration of 3D Angiographic and X-Ray Images Using Sequential Monte
Carlo Sampling,
CVBIA05(427-436).
WWW Version.
0601
See also Shape Registration in Implicit Spaces Using Information Theory and Free Form Deformations.
BibRef
Groger, M.,
Sepp, W.,
Hirzinger, G.,
Structure Driven Substitution of Specular Reflections for Realtime
Heart Surface Tracking,
ICIP05(II: 1066-1069).
WWW Version.
0512
BibRef
Bogunovic, H.[Hrvoje],
Loncaric, S.[Sven],
Denoising of Time-Density Data in Digital Subtraction Angiography,
SCIA05(1157-1166).
WWW Version.
0506
BibRef
Valet, G.,
Sanchez, S.,
Lopez-Hernandez, J.M.,
Daul, C.,
Wolf, D.,
Karcher, G.,
Towards a new diagnosis aid of cardiovascular diseases using
2d-multimodal data registration and 3d-data superimposition,
ICIP04(III: 1907-1910).
WWW Version.
0505
BibRef
Paul, R.V.,
Pattichis, M.S.,
Nested random phase sequence sets: a link between AM-FM demodulation
and increasing operators with application to cardiac image analysis,
Southwest04(196-200).
IEEE Abstract. IEEE Top Reference.
0411
BibRef
Lingrand, D.[Diane],
Charnoz, A.[Arnaud],
Koulibaly, P.M.[Pierre Malick],
Darcourt, J.[Jacques],
Montagnat, J.[Johan],
Toward Accurate Segmentation of the LV Myocardium and Chamber for
Volumes Estimation in Gated SPECT Sequences,
ECCV04(Vol IV: 267-278).
WWW Version.
0405
BibRef
Seringaoglu, Y.,
Brooks, D.H.,
MacLeod, R.S.,
A Bayesian approach to inclusion and performance analysis of using
extra information in bioelectric inverse problems,
ICIP03(I: 1089-1092).
IEEE Abstract. IEEE Top Reference.
0312
BibRef
Brooks, D.H.,
MacLeod, R.S.,
Imaging the Electrical Activity of the Heart:
Direct and Inverse Approaches,
ICIP94(III: 548-552).
WWW Version.
9411
BibRef
Richter, J.[Jens],
Ericsson, A.[Anders],
Aström, K.[Kalle],
Kahl, F.[Fredrik],
Edenbrant, L.[Lars],
Automated Interpretation of Cardiac Scintigrams,
SCIA03(565-570).
WWW Version.
0310
BibRef
Liu, H.F.[Hua-Feng],
Shi, P.C.[Peng-Cheng],
Simultaneous estimation of left ventricular motion and material
properties with maximum a posteriori strategy,
CVPR03(I: 161-168).
IEEE Abstract. IEEE Top Reference.
0307
BibRef
Corona, E.,
Mitra, S.,
Wilson, M.,
A fast algorithm for registration of individual frames and information
recovery in fluorescein angiography video image analysis,
Southwest02(265-268).
IEEE Top Reference.
0208
BibRef
Christiaens, J.,
van de Walle, R.,
Lemahieu, I.,
A Simple Determination System for Optimal Angiographic Viewing Angles
and QCA Parameters,
ICIP01(II: 327-330).
IEEE Abstract. IEEE Top Reference.
0108
BibRef
Olivieri, D.N.,
Vega, F.,
Image Prototype Similarity Matching for Lymph Node Hemopathology,
ICPR00(Vol II: 279-282).
WWW Version.
HTML Version.
0009
BibRef
Newman, T.S.,
Yi, H.,
Compound Extraction and Fitting Method for Detecting Cardiac Ventricle
in SPECT Data,
ICPR00(Vol IV: 328-331).
WWW Version.
HTML Version.
0009
BibRef
de Murcia, J.,
Grangeat, P.,
Spatio-temporally regularized reconstruction of gated SPECT myocardial
image sequences,
ICIP96(II: 721-724).
WWW Version.
9610
BibRef
Coutand, F.,
Garnero, L.,
Fonroget, J.,
Anatomical data fusion for quantitative reconstruction in cardiac
tomoscintigraphy using active contours of the organs of the thorax,
ICIP96(II: 733-736).
WWW Version.
9610
BibRef
Mojsilovic, A.,
Popovic, M.,
Popovic, A.,
Neskovic, A.,
Obradovic, V.,
Analysis and characterization of myocardial tissue with the wavelet
image extension,
ICIP95(II: 504-507).
WWW Version.
9510ultrasound.
BibRef
Yeung, M.M.,
Yeo, B.L.,
Liou, S.P.,
Bani-Hashemi, A.,
Three-Dimensional Image Registration for Spiral CT Angiography,
CVPR94(423-429).
IEEE Abstract. IEEE Top Reference.
BibRef
9400
Brigger, P.,
Bacharach, S.,
Aldroubi, A., and
Unser, M.,
Segmentation of Gated SPECT Images for Automatic Computation of
Myocardial Volume and Ejection Fraction,
ICIP97(II: 113-116).
WWW Version.
BibRef
9700
Dumay, A.C.M.,
van der Geest, R.J.,
Gerbrands, J.J.,
Jansen, E.,
Reiber, J.H.C.,
Consistent inexact graph matching applied to labelling coronary
segments in arteriograms,
ICPR92(III:439-442).
WWW Version.
9208
BibRef
Bao, Y.,
Stiehl, H.S.,
The epipolar line constraint for precise biplane angiogram analysis,
ICPR92(III:485-488).
WWW Version.
9208
BibRef
Tehrani, S.,
Weymouth, T.E.,
Mancini, G.B.J.,
Knowledge-guided left ventricular boundary detection,
CVPR89(342-347).
IEEE Abstract. IEEE Top Reference.
0403
BibRef
Chapter on Medical Applications, CAT, MRI, Ultrasound, Heart Models, Brain Models continues in
Heart, Cardiac, Angiography using MRI Analysis .