20.10 Medical Applications -- Heart, Cardiac Applications

Chapter Contents (Back)
Heart. Cardiac. See also Tracking Applied to Heart Images. See also Deformable Models, Cardiac Motion Models for Volumes, Left Ventricle.

Tsuji, S.[Saburo], Osada, M., and Yachida, M.[Masahiko],
Tracking and Segmentation of Moving Objects in Dynamic Line Images,
PAMI(2), No. 6, November 1980, pp. 516-522. BibRef 8011
Earlier:
Three Dimensional Movement Analysis of Dynamic Line Images,
IJCAI79(896-901). Matching, Contours. Snakes. Flexible template match with corresponding segments, group by similarity of motion of the segments. BibRef

Yachida, M.[Masahiko], Ikeda, M.[Motozo], and Tsuji, S.[Saburo],
A Plan-Guided Analysis of Cineangiograms for Measurement of Dynamic Behavior of Heart Wall,
PAMI(2), No. 6, November 1980, pp. 537-543. BibRef 8011
Earlier:
Plan Guided Analysis of Noisy Dynamic Images,
IJCAI79(978-983). BibRef

Cavouras, D., Wayne, L.N.[L. Norton],
Tomographic mapping of the activity of the heart wall,
PR(14), No. 1-6, 1981, pp. 17-32.
WWW Version. 0309 BibRef

Bunke, H., Sagerer, G., Niemann, H.,
Model Based Analysis of Scintigraphic Image Sequences of the Human Heart,
ISPDSA83(725-740). BibRef 8300

Gerbrands, J.J., Slump, C.H.,
3-D Reconstruction of Homogeneous Objects from two Poisson-Distributed Projections,
PRL(3), 1985, pp. 137-145. BibRef 8500

Slump, C.H., Gerbrands, J.J.,
A Network Flow Approach to Reconstruction of the Left Ventricle from Two Projections,
CGIP(18), No. 1, January 1982, pp. 18-36.
WWW Version. BibRef 8201

Ritchings, R.T., Colchester, A.C.F., Wang, H.Q.,
Knowledge-Based Analysis of Carotid Angiograms,
IVC(3), No. 4, November 1985, pp. 217-222.
WWW Version. BibRef 8511

Acharya, R.S., Heffernan, P., Robb, R.A.,
High-Speed 3D Imaging of the Beating Heart Using Temporal Estimation,
CVGIP(39), No. 3, September 1987, pp. 279-290. BibRef 8709

Chou, W.S.[Wen-Shou], Wu, C.M.[Chung-Ming], Chen, Y.C.[Yung-Chang], Hsieh, K.S.[Kai-Sheng],
Detecting myocardial boundaries of left ventricle from a single frame 2DE image,
PR(23), No. 7, 1990, pp. 799-806.
WWW Version. 0401 BibRef

Tsai, C.T.[Ching-Tsorng], Sun, Y.N.[Yung-Nien], Chung, P.C.[Pau-Choo], Lee, J.S.[Jiann-Shu],
Endocardial boundary detection using a neural network,
PR(26), No. 7, July 1993, pp. 1057-1068.
WWW Version. 0401 BibRef

Baroni, M.[Maurizio], Barletta, G.[Giuseppe],
Digital curvature estimation for left ventricular shape analysis,
IVC(10), No. 7, September 1992, pp. 485-494.
WWW Version. 0401 BibRef

Solaiyappan, M., Poston, T., Heng, P.A., McVeigh, E.R., Guttman, M.A., Zerhouni, E.A.,
Interactive Visualization for Rapid Noninvasive Cardiac Assessment,
Computer(29), No. 1, January 1996, pp. 55-62. BibRef 9601

Prause, G.P.M., Onnasch, D.G.W.,
Binary reconstruction of the heart chambers from biplane angiographic image sequences,
MedImg(15), No. 4, August 1996, pp. 532-546.
IEEE Top Reference. 0203 BibRef

Wang, H.Q., Ritchings, R.T.,
Image Understanding System for Carotid Angiograms,
IVC(5), No. 2, May 1987, pp. 79-83.
WWW Version. BibRef 8705

Ritchings, R.T., Colchester, A.C.F.,
Detection of Abnormalities on Carotid Angiograms Using Syntactic Techniques,
PRL(4), 1986, pp. 367-374. BibRef 8600

Higgins, W.E., Spyra, W.J.T., Karwoski, R.A., Ritman, E.L.[Erik L.],
System for analyzing high-resolution three-dimensional coronary angiograms,
MedImg(15), No. 3, June 1996, pp. 377-385.
IEEE Top Reference. 0203 BibRef

Ho, B.K.T., Tsai, M.J.[Min-Jen], Wei, J.[Jun], Ma, M., Saipetch, P.,
Video compression of coronary angiograms based on discrete wavelet transform with block classification,
MedImg(15), No. 6, December 1996, pp. 814-823.
IEEE Top Reference. 0203 BibRef

Ezquerra, N., Capell, S., Klein, L., Duijves, P.,
Model-Guided Labeling of Coronary Structure,
MedImg(17), No. 3, June 1998, pp. 429-441.
IEEE Top Reference. 9809 BibRef

Nalcioglu, O., Roeck, W.W., Reese, T., Qu, L.Z., Tobis, J.M., Henry, W.L.,
Background subtraction algorithms for videodensitometric quantification of coronary stenosis,
MVA(1), No. 3, 1988, pp. 155-162. BibRef 8800

Suri, J.S.[Jasjit S.],
Computer Vision, Pattern Recognition and Image Processing in Left Ventricle Segmentation: The Last 50 Years,
PAA(3), No. 3 2000, pp. 209-242. 0010 Survey, Segmentation. BibRef

Bonciu, C., Weber, R., Léger, C.,
4D reconstruction of the left ventricle during a single heart beat from ultrasound imaging,
IVC(19), No. 6, April 2001, pp. 401-412.
WWW Version. 0105 BibRef

Setarehdan, S.K., and Soraghan, J.J.,
Automatic cardiac LV boundary detection and tracking using hybrid fuzzy temporal and fuzzy multiscale edge detection,
BiomedEng(46), No. 11, November 1999, pp. 1364-1378. BibRef 9911

Sheikh Akbari, A., Soraghan, J.J.,
Fuzzy-Based Multiscale Edge Detection,
IEE-P(Electronics Letters 39), No. 1, 2003, pp. 30-32. BibRef 0300

Sheikh Akbari, A., Soraghan, J.J.,
Multiscale fuzzy reasoning (MFR) for automatic object extraction,
PRL(26), No. 1, 1 January 2005, pp. 77-81.
WWW Version. 0501 BibRef

Narayanan, M.V., King, M.A., Wernick, M.N., Byrne, C.L., Soares, E.J., Pretorius, P.H.,
Improved image quality and computation reduction in 4-D reconstruction of cardiac-gated SPECT images,
MedImg(19), No. 5, May 2000, pp. 423-433.
IEEE Top Reference. 0110 BibRef

Jin, M.[Mingwu], Yang, Y.Y.[Yong-Yi], Wernick, M.N.,
Reconstruction of Cardiac-Gated Dynamic SPECT Images,
ICIP05(III: 752-755).
WWW Version. 0512 BibRef

Frangi, A.F., Niessen, W.J., Viergever, M.A.,
Three-dimensional modeling for functional analysis of cardiac images: A Review,
MedImg(20), No. 1, January 2001, pp. 2-5.
IEEE Top Reference. 0110 BibRef

Frangi, A.F., Rueckert, D., Schnabel, J.A., Niessen, W.J.,
Automatic construction of multiple-object three-dimensional statistical shape models: application to cardiac modeling,
MedImg(21), No. 9, September 2002, pp. 1151-1166.
IEEE Top Reference. 0301 See also Automatic construction of 3-D statistical deformation models of the brain using nonrigid registration. BibRef

Rogowska, J., Brezinski, M.E.,
Evaluation of the adaptive speckle suppression filter for coronary optical coherence tomography imaging,
MedImg(19), No. 12, December 2000, pp. 1261-1266.
IEEE Top Reference. 0110 BibRef

Sui, L.[Lei], Haralick, R.M.[Robert M.], Sheehan, F.H.[Florence H.],
A Knowledge-Based Boundary Delineation System for Contrast Ventriculograms,
ITBio(5), No. 2, June 2001, pp. 116-132. BibRef 0106

Suri, J.S.[Jasjit S.], Haralick, R.M.[Robert M.], Sheehan, F.H.[Florence H.],
Automatic Quadratic Calibration for Correction of Pixel Classifier Boundaries to an Accuracy of 2.5mm: An Application in X-ray Heart Imaging,
ICPR98(Vol I: 30-33).
WWW Version. 9808 BibRef
Earlier:
Left Ventricle Longitudinal Axis Fitting and its Apex Estimation Using A Robust Algorithm and its Performance: A Parametric Apex Model,
ICIP97(III: 118-121).
WWW Version. BibRef

Debreuve, É.[Éric], Barlaud, M.[Michel], Aubert, G.[Gilles], Laurette, I., Darcourt, J.,
Space-time segmentation using level set active contours applied to myocardial gated SPECT,
MedImg(20), No. 7, July 2001, pp. 643-659.
IEEE Top Reference. 0110 BibRef

Amadieu, O.[Olivier], Debreuve, E.[Eric], Barlaud, M.[Michel], Aubert, G.[Gilles],
Inward and Outward Curve Evolution Using Level Set Method,
ICIP99(III:188-192).
IEEE Abstract. IEEE Top Reference. BibRef 9900

Talukdar, A.S., Wilson, D.L.,
Modeling and optimization of rotational C-arm stereoscopic X-ray angiography,
MedImg(18), No. 7, July 1999, pp. 604-616.
IEEE Top Reference. 0110 BibRef

Ning, R.[Ruola], Chen, B.[Biao], Yu, R.F.[Rong-Feng], Conover, D., Tang, X.Y.[Xiang-Yang], Ning, Y.[Yi],
Flat panel detector-based cone-beam volume CT angiography imaging: system evaluation,
MedImg(19), No. 9, September 2000, pp. 949-963.
IEEE Top Reference. 0110 BibRef

Kump, K.S., Saidel, G.M., Wilson, D.L.,
Comparison of algorithms for combining X-ray angiography images,
MedImg(20), No. 8, August 2001, pp. 742-750.
IEEE Top Reference. 0110 BibRef

Jani, A.B., Pelizzari, C.A., Chen, G.T.Y., Roeske, J., Hamilton, R.J., MacDonald, R.L., Bova, F., Hoffmann, K.R., Sweeney, P.A.,
Volume rendering quantification algorithm for reconstruction of CT volume-rendered structures. 1. Cerebral arteriovenous malformations,
MedImg(19), No. 1, January 2000, pp. 12-24.
IEEE Top Reference. 0110 BibRef

Close, R.A., Abbey, C.K., Morioka, C.A., Whiting, J.S.,
Accuracy assessment of layer decomposition using simulated angiographic image sequences,
MedImg(20), No. 10, October 2001, pp. 990-998.
IEEE Top Reference. 0111 BibRef

Behloul, F., Lelieveldt, B.P.F., Boudraa, A., Janier, M.F., Revel, D., Reiber, J.H.C.,
Neuro-fuzzy systems for computer-aided myocardial viability assessment,
MedImg(20), No. 12, December 2001, pp. 1302-1313.
IEEE Top Reference. 0201 BibRef

Hoetink, A.E., Faes, T.J.C., Marcus, J.T., Kerkkamp, H.J.J., Heethaar, R.M.,
Imaging of thoracic blood volume changes during the heart cycle with electrical impedance using a linear spot-electrode array,
MedImg(21), No. 6, June 2002, pp. 653-661.
IEEE Top Reference. 0208 BibRef

Semenov, S.Y., Svenson, R.H., Posukh, V.G., Nazarov, A.G., Sizov, Y.E., Bulyshev, A.E., Souvorov, A.E., Chen, W., Kasell, J., Tatsis, G.P.,
Dielectrical spectroscopy of canine myocardium during acute ischemia and hypoxia at frequency spectrum from 100 khz to 6 ghz,
MedImg(21), No. 6, June 2002, pp. 703-707.
IEEE Top Reference. 0208 BibRef

Moriyama, M., Sato, Y., Naito, H., Hanayama, M., Ueguchi, T., Harada, T., Yoshimoto, F., Tamura, S.,
Reconstruction of time-varying 3-d left-ventricular shape from multiview x-ray cineangiocardiograms,
MedImg(21), No. 7, July 2002, pp. 773-785.
IEEE Top Reference. 0210 BibRef

Canero, C., Vilarino, F., Mauri, J., Radeva, P.I.,
Predictive (un)distortion model and 3-D reconstruction by biplane snakes,
MedImg(21), No. 9, September 2002, pp. 1188-1201.
IEEE Top Reference. 0301 BibRef

Gil, D., Hernandez, A., Rodriguez, O., Mauri, J., Radeva, P.I.,
Statistical Strategy for Anisotropic Adventitia Modelling in IVUS,
MedImg(25), No. 6, June 2006, pp. 768-778.
WWW Version. 0606 BibRef

Gil, D., Rodriguez-Leor, O., Radeva, P.I., Mauri, J.,
Myocardial Perfusion Characterization From Contrast Angiography Spectral Distribution,
MedImg(27), No. 5, May 2008, pp. 641-649.
WWW Version. 0711 BibRef

Makela, T., Clarysse, P., Sipila, O., Pauna, N., Pham, Q.C.[Quoc Cuong], Katila, T., Magnin, I.E.,
A review of cardiac image registration methods,
MedImg(21), No. 9, September 2002, pp. 1011-1021.
IEEE Top Reference. 0301 BibRef

Tilg, B., Fischer, G., Modre, R., Hanser, F., Messnarz, B., Schocke, M., Kremser, C., Berger, T., Hintringer, F., Roithinger, F.X.,
Model-based imaging of cardiac electrical excitation in humans,
MedImg(21), No. 9, September 2002, pp. 1031-1039.
IEEE Top Reference. 0301 BibRef

Frangl, A.F., Rueckert, D., Duncan, J.S.,
Three-dimensional cardiovascular image analysis,
MedImg(21), No. 9, September 2002, pp. 1005-1010.
IEEE Top Reference. 0301 BibRef

Sheehan, F.H., Bolson, E.L., McDonald, J.A., Reisman, M., Koch, K., Poppas, A.,
Method for three-dimensional data registration from disparate imaging modalities in the NOGA myocardial viability trial,
MedImg(21), No. 10, October 2002, pp. 1264-1270.
IEEE Top Reference. 0301 BibRef

Nguyen, T.D., Reeves, S.J., Denney, Jr., T.S.,
On the optimality of magnetic resonance tag patterns for heart wall motion estimation,
IP(12), No. 5, May 2003, pp. 524-532.
WWW Version. 0307 BibRef
Earlier:
New magnetic resonance tagging technique for directly measuring the strain tensor of the in vivo human heart,
ICIP98(I: 694-698).
WWW Version. 9810 BibRef

Denney, Jr., T.S., Prince, J.L., Lopez, M.J., McVeigh, E.R.,
Optimal tag pattern validation using magnetic resonance imaging,
ICIP94(I: 881-885).
WWW Version. 9411 BibRef

Yan, L.[Litao], Denney, Jr., T.S.,
Unsupervised estimation of left ventricular displacement from MR tagged images using Markov random field edge priors,
ICIP98(I: 689-693).
WWW Version. 9810 BibRef

Ghanem, R.N., Ramanathan, C., Jia, P.[Ping], Rudy, Y.,
Heart-surface reconstruction and ECG electrodes localization using fluoroscopy, epipolar geometry and stereovision: application to noninvasive imaging of cardiac electrical activity,
MedImg(22), No. 10, October 2003, pp. 1307-1318.
IEEE Abstract. IEEE Top Reference. 0310 BibRef

Sornborger, A., Sirovich, L., Morley, G.,
Extraction of periodic multivariate signals: mapping of voltage-dependentdye fluorescence in the mouse heart,
MedImg(22), No. 12, December 2003, pp. 1537-1549.
IEEE Abstract. IEEE Top Reference. 0401 BibRef

Piliouras, N., Kalatzis, I., Theocharakis, P., Dimitropoulos, N., Cavouras, D.,
Development of the probabilistic neural network-cubic least squares mapping (PNN-LSM3) classifier to assess carotid plaque's risk,
PRL(25), No. 2, January 2004, pp. 249-258.
WWW Version. 0401 BibRef

Suzuki, K., Horiba, I., Sugie, N., Nanki, M.,
Extraction of Left Ventricular Contours From Left Ventriculograms by Means of a Neural Edge Detector,
MedImg(23), No. 3, March 2004, pp. 330-339.
IEEE Abstract. IEEE Top Reference. 0403 BibRef

Medina, R., Garreau, M., Toro, J., Coatrieux, J.L., Jugo, D.,
Three-Dimensional Reconstruction of the Left Ventricle From Two Angiographic Views: An Evidence Combination Approach,
SMC-A(34), No. 3, May 2004, pp. 359-370.
IEEE Abstract. IEEE Top Reference. 0404 BibRef

Medina, R., Garreau, M., Toro, J., Breton, H.L., Coatrieux, J.L., Jugo, D.,
Markov Random Field Modeling for Three-Dimensional Reconstruction of the Left Ventricle in Cardiac Angiography,
MedImg(25), No. 8, August 2006, pp. 1087-1100.
WWW Version. 0608 BibRef

Brusseau, E., de Korte, C.L., Mastik, F., Schaar, J., van der Steen, A.F.W.,
Fully automatic luminal contour segmentation in intracoronary ultrasound imaging-a statistical approach,
MedImg(23), No. 5, May 2004, pp. 554-566.
IEEE Abstract. IEEE Top Reference. 0406 BibRef

Zhang, Y.N.[Ya-Ni], Pham, B.T., Eckstein, M.P.,
Automated optimization of JPEG 2000 encoder options based on model observer performance for detecting variable signals in X-ray coronary angiograms,
MedImg(23), No. 4, April 2004, pp. 459-474.
IEEE Abstract. IEEE Top Reference. 0406 BibRef

Zhang, Y.N.[Ya-Ni], Pham, B.T., Eckstein, M.P.,
Evaluation of JPEG 2000 encoder options: human and model observer detection of variable signals in X-ray coronary angiograms,
MedImg(23), No. 5, May 2004, pp. 613-632.
IEEE Abstract. IEEE Top Reference. 0406 BibRef

Zhang, Y.N.[Ya-Ni], Pham, B.T., Eckstein, M.P.,
The Effect of Nonlinear Human Visual System Components on Performance of a Channelized Hotelling Observer in Structured Backgrounds,
MedImg(25), No. 10, October 2006, pp. 1348-1362.
WWW Version. 0609 BibRef

Remme, E.W., Augenstein, K.F., Young, A.A., Hunter, P.J.,
Parameter Distribution Models for Estimation of Population Based Left Ventricular Deformation Using Sparse Fiducial Markers,
MedImg(24), No. 3, March 2005, pp. 381-388.
IEEE Abstract. IEEE Top Reference. 0501 BibRef

Himel, IV, H.D., Knisley, S.B.,
Imaging of Cardiac Movement Using Ratiometric and Nonratiometric Optical Mapping: Effects of Ischemia and 2, 3-Butaneodione Monoxime,
MedImg(25), No. 1, January 2006, pp. 122-127.
WWW Version. 0601 BibRef

Kim, D.Y.[Do Yeon], Park, J.W.[Jong Won],
Connectivity-based local adaptive thresholding for carotid artery segmentation using MRA images,
IVC(23), No. 14, 12 December 2005, pp. 1277-1287.
WWW Version. 0601 BibRef

Sermesant, M., Delingette, H., Ayache, N.,
An Electromechanical Model of the Heart for Image Analysis and Simulation,
MedImg(25), No. 5, May 2006, pp. 612-625.
WWW Version. 0605 BibRef

Lauritsch, G., Boese, J., Wigstrom, L., Kemeth, H., Fahrig, R.,
Towards Cardiac C-Arm Computed Tomography,
MedImg(25), No. 7, July 2006, pp. 922-934.
WWW Version. 0606 BibRef

Schafer, D., Borgert, J., Rasche, V., Grass, M.,
Motion-Compensated and Gated Cone Beam Filtered Back-Projection for 3-D Rotational X-Ray Angiography,
MedImg(25), No. 7, July 2006, pp. 898-906.
WWW Version. 0606 BibRef

Polat, K.[Kemal], Günes, S.[Salih], Tosun, S.[Sülayman],
Diagnosis of heart disease using artificial immune recognition system and fuzzy weighted pre-processing,
PR(39), No. 11, November 2006, pp. 2186-2193.
WWW Version. 0608Heart disease; Artificial immune system; AIRS; Fuzzy weighted pre-processing; k-fold cross validation; Medical diagnosis BibRef

Oost, E., Koning, G., Sonka, M., Oemrawsingh, P.V., Reiber, J.H.C., Lelieveldt, B.P.F.,
Automated contour detection in X-ray left ventricular angiograms using multiview active appearance models and dynamic programming,
MedImg(25), No. 9, September 2006, pp. 1158-1171.
WWW Version. 0609 BibRef

Dehmeshki, J., Ye, X., Amin, H., Abaei, M., Lin, X., Qanadli, S.D.,
Volumetric Quantification of Atherosclerotic Plaque in CT Considering Partial Volume Effect,
MedImg(26), No. 3, March 2007, pp. 273-282.
WWW Version. 0703 BibRef

Liu, H.F.[Hua-Feng], Shi, P.C.[Peng-Cheng],
State-Space Analysis of Cardiac Motion With Biomechanical Constraints,
IP(16), No. 4, April 2007, pp. 901-917.
WWW Version. 0704 BibRef

Wong, K., Liu, H.F.[Hua-Feng], Sinusas, A.J.[Albert J.], Shi, P.C.[Peng-Cheng],
Multiframe nonrigid motion analysis with anisotropic spatial constraints: applications to cardiac image analysis,
ICIP04(I: 131-134).
WWW Version. 0505 BibRef

Tong, S.[Shan], Sinusas, A.J.[Albert J.], Shi, P.C.[Peng-Cheng],
Sampled-Data H- Filtering for Robust Kinematics Estimation: Applications to Biomechanics-Based Cardiac Image Analysis,
ICIP06(2525-2528). 0610
WWW Version. BibRef
And:
Continuous-Discrete Filtering for Cardiac Kinematics Estimation under Spatio-Temporal Biomechanical Constrains,
ICPR06(I: 167-170).
WWW Version. 0609 BibRef

Sang, N.[Nong], Li, H.[Heng], Peng, W.X.[Wei-Xue], Zhang, T.X.[Tian-Xu],
Knowledge-based adaptive thresholding segmentation of digital subtraction angiography images,
IVC(25), No. 8, 1 August 2007, pp. 1263-1270.
WWW Version. 0706Digital subtraction angiography; Adaptive threshold; The busyness BibRef

Bharkhada, D.[Deepak], Yu, H.Y.[Heng-Yong], Zeng, K.[Kai], Bai, E.W.[Er-Wei], Wang, G.[Ge],
A comparative study on interpolation methods for controlled cardiac CT,
IJIST(17), No. 2, 2007, pp. 91-98.
WWW Version. 0710 BibRef


Tranquillo, J.[Joseph], Sunkara, A.[Adhira],
Can We Trust the Transgenic Mouse? Insights from Computer Simulations,
FIMH07(210-219).
WWW Version. 0706 BibRef

Kroon, W.[Wilco], Delhaas, T.[Tammo], Arts, T.[Theo], Bovendeerd, P.[Peter],
Constitutive Modeling of Cardiac Tissue Growth,
FIMH07(340-349).
WWW Version. 0706 BibRef

Gilbert, S.H.[Stephen H.], Benson, A.P.[Alan P.], Li, P.[Pan], Holden, A.V.[Arun V.],
Visualisation of Dog Myocardial Structure from Diffusion Tensor Magnetic Resonance Imaging: The Paradox of Uniformity and Variability,
FIMH07(403-412).
WWW Version. 0706 BibRef

Kumar, D.[Dinesh], Shen, D.G.[Ding-Gang], Wei, L.[Liyang], Turlapthi, R.[Ram], Suri, J.S.[Jasjit S.],
Motion Correction Strategies for Interventional Angiography Images: A Comparative Approach,
ICIP07(I: 497-500).
WWW Version. 0709 BibRef

Bravo, A.[Antonio], Medina, R.[Rubén], Díaz, J.A.[J. Arelis],
A Clustering Based Approach for Automatic Image Segmentation: An Application to Biplane Ventriculograms,
CIARP06(316-325).
WWW Version. 0611 BibRef

Chan, M.Y.[Ming-Yuen], Qu, H.[Huamin], Wu, Y.C.[Ying-Cai], Zhou, H.[Hong],
Viewpoint Selection for Angiographic Volume,
ISVC06(I: 528-537).
WWW Version. 0611 BibRef

Condurache, A.P., Aach, T., Kaiser, A., Radke, P.,
User-defined ROI tracking for estimation of the myocardial blush grade,
Southwest06(66-70).
WWW Version. 0603 BibRef

Yu, G.[Gang], Wang, C.G.[Chang-Guo], Li, P.[Peng], Miao, Y.[Yalin], Bian, Z.[Zhengzhong],
A Statistical Level Set Framework for Segmentation of Left Ventricle,
IWICPAS06(396-405).
WWW Version. 0608 BibRef

Rocha, R.[Rui], Campilho, A.[Aurélio], Silva, J.[Jorge],
Segmentation of Ultrasonic Images of the Carotid,
ICIAR05(949-957).
WWW Version. 0509 BibRef

Xue, X.[Xinwei],
Interactive 3D Heart Chamber Partitioning with a New Marker-Controlled Watershed Algorithm,
ISVC05(92-99).
WWW Version. 0512 BibRef

Noble, J.A.[J. Alison],
Cardiology Meets Image Analysis: Just an Application or Can Image Analysis Usefully Impact Cardiology Practice?,
CVBIA05(25-30).
WWW Version. 0601 BibRef

Zhuang, L.[Ling], Liu, H.F.[Hua-Feng], Chen, W.[Wei], Bao, H.J.[Hu-Jun], Shi, P.C.[Peng-Cheng],
Simultaneous Segmentation and Motion Recovery in 3D Cardiac Image Analysis,
CVBIA05(499-507).
WWW Version. 0601 BibRef

Florin, C.[Charles], Williams, J.[James], Khamene, A.[Ali], Paragios, N.[Nikos],
Registration of 3D Angiographic and X-Ray Images Using Sequential Monte Carlo Sampling,
CVBIA05(427-436).
WWW Version. 0601 See also Shape Registration in Implicit Spaces Using Information Theory and Free Form Deformations. BibRef

Groger, M., Sepp, W., Hirzinger, G.,
Structure Driven Substitution of Specular Reflections for Realtime Heart Surface Tracking,
ICIP05(II: 1066-1069).
WWW Version. 0512 BibRef

Bogunovic, H.[Hrvoje], Loncaric, S.[Sven],
Denoising of Time-Density Data in Digital Subtraction Angiography,
SCIA05(1157-1166).
WWW Version. 0506 BibRef

Valet, G., Sanchez, S., Lopez-Hernandez, J.M., Daul, C., Wolf, D., Karcher, G.,
Towards a new diagnosis aid of cardiovascular diseases using 2d-multimodal data registration and 3d-data superimposition,
ICIP04(III: 1907-1910).
WWW Version. 0505 BibRef

Paul, R.V., Pattichis, M.S.,
Nested random phase sequence sets: a link between AM-FM demodulation and increasing operators with application to cardiac image analysis,
Southwest04(196-200).
IEEE Abstract. IEEE Top Reference. 0411 BibRef

Lingrand, D.[Diane], Charnoz, A.[Arnaud], Koulibaly, P.M.[Pierre Malick], Darcourt, J.[Jacques], Montagnat, J.[Johan],
Toward Accurate Segmentation of the LV Myocardium and Chamber for Volumes Estimation in Gated SPECT Sequences,
ECCV04(Vol IV: 267-278).
WWW Version. 0405 BibRef

Seringaoglu, Y., Brooks, D.H., MacLeod, R.S.,
A Bayesian approach to inclusion and performance analysis of using extra information in bioelectric inverse problems,
ICIP03(I: 1089-1092).
IEEE Abstract. IEEE Top Reference. 0312 BibRef

Brooks, D.H., MacLeod, R.S.,
Imaging the Electrical Activity of the Heart: Direct and Inverse Approaches,
ICIP94(III: 548-552).
WWW Version. 9411 BibRef

Richter, J.[Jens], Ericsson, A.[Anders], Aström, K.[Kalle], Kahl, F.[Fredrik], Edenbrant, L.[Lars],
Automated Interpretation of Cardiac Scintigrams,
SCIA03(565-570).
WWW Version. 0310 BibRef

Liu, H.F.[Hua-Feng], Shi, P.C.[Peng-Cheng],
Simultaneous estimation of left ventricular motion and material properties with maximum a posteriori strategy,
CVPR03(I: 161-168).
IEEE Abstract. IEEE Top Reference. 0307 BibRef

Corona, E., Mitra, S., Wilson, M.,
A fast algorithm for registration of individual frames and information recovery in fluorescein angiography video image analysis,
Southwest02(265-268).
IEEE Top Reference. 0208 BibRef

Christiaens, J., van de Walle, R., Lemahieu, I.,
A Simple Determination System for Optimal Angiographic Viewing Angles and QCA Parameters,
ICIP01(II: 327-330).
IEEE Abstract. IEEE Top Reference. 0108 BibRef

Olivieri, D.N., Vega, F.,
Image Prototype Similarity Matching for Lymph Node Hemopathology,
ICPR00(Vol II: 279-282).
WWW Version.
HTML Version. 0009 BibRef

Newman, T.S., Yi, H.,
Compound Extraction and Fitting Method for Detecting Cardiac Ventricle in SPECT Data,
ICPR00(Vol IV: 328-331).
WWW Version.
HTML Version. 0009 BibRef

de Murcia, J., Grangeat, P.,
Spatio-temporally regularized reconstruction of gated SPECT myocardial image sequences,
ICIP96(II: 721-724).
WWW Version. 9610 BibRef

Coutand, F., Garnero, L., Fonroget, J.,
Anatomical data fusion for quantitative reconstruction in cardiac tomoscintigraphy using active contours of the organs of the thorax,
ICIP96(II: 733-736).
WWW Version. 9610 BibRef

Mojsilovic, A., Popovic, M., Popovic, A., Neskovic, A., Obradovic, V.,
Analysis and characterization of myocardial tissue with the wavelet image extension,
ICIP95(II: 504-507).
WWW Version. 9510ultrasound. BibRef

Yeung, M.M., Yeo, B.L., Liou, S.P., Bani-Hashemi, A.,
Three-Dimensional Image Registration for Spiral CT Angiography,
CVPR94(423-429).
IEEE Abstract. IEEE Top Reference. BibRef 9400

Brigger, P., Bacharach, S., Aldroubi, A., and Unser, M.,
Segmentation of Gated SPECT Images for Automatic Computation of Myocardial Volume and Ejection Fraction,
ICIP97(II: 113-116).
WWW Version. BibRef 9700

Dumay, A.C.M., van der Geest, R.J., Gerbrands, J.J., Jansen, E., Reiber, J.H.C.,
Consistent inexact graph matching applied to labelling coronary segments in arteriograms,
ICPR92(III:439-442).
WWW Version. 9208 BibRef

Bao, Y., Stiehl, H.S.,
The epipolar line constraint for precise biplane angiogram analysis,
ICPR92(III:485-488).
WWW Version. 9208 BibRef

Tehrani, S., Weymouth, T.E., Mancini, G.B.J.,
Knowledge-guided left ventricular boundary detection,
CVPR89(342-347).
IEEE Abstract. IEEE Top Reference. 0403 BibRef

Chapter on Medical Applications, CAT, MRI, Ultrasound, Heart Models, Brain Models continues in
Heart, Cardiac, Angiography using MRI Analysis .


Last update:Jun 25, 2008 at 13:37:57