20.10.3.2 Blood Flow Analysis

Chapter Contents (Back)
Blood Vessels.

Fu, L.[LiMin], Yang, M.[Mark], Braylan, R.[Raul], Benson, N.[Neal],
Real-time adaptive clustering of flow cytometric data,
PR(26), No. 2, February 1993, pp. 365-373.
WWW Version. 0401 BibRef

Chen, K.W., Lawson, M., Reiman, E., Cooper, A., Feng, D.G., Huang, S.C., Bandy, D., Ho, D., Yun, L.S., Palant, A.,
Generalized Linear Least Squares Method for Fast Generation of Myocardial Blood Flow Parametric Images with N-13 Ammonia PET,
MedImg(17), No. 2, April 1998, pp. 236-243.
IEEE Top Reference. 9808 BibRef

Watabe, W., Channing, M.A., Riddell, C., Jousse, F., Libutti, S.K., Carrasquillo, J.A., Bacharach, S.L., Carson, R.E.,
Noninvasive estimation of the aorta input function for measurement of tumor blood flow with O15 water,
MedImg(20), No. 3, March 2001, pp. 164-174.
IEEE Top Reference. 0110 BibRef

Pajevic, S., Bacharach, S.L., Carson, R.E., Weiss, G.H.,
Effects of time delay in cardiac blood flow measurements by bolus H2 ^15 O,
MedImg(16), No. 3, June 1997, pp. 294-300.
IEEE Top Reference. 0205 BibRef

Schmitt, H., Grass, M., Rasche, V., Schramm, O., Haehnel, S., Sartor, K.,
An X-ray-based method for the determination of the contrast agent propagation in 3-D vessel structures,
MedImg(21), No. 3, March 2002, pp. 251-262.
IEEE Top Reference. 0205 BibRef
And: Correction: MedImg(21), No. 7, July 2002, pp. 837-838.
IEEE Top Reference. 0210 BibRef

Androutsos, D., Trahanias, P.E., Venetsanopoulos, A.N.,
Application of active contours for photochromic tracer flow extraction,
MedImg(16), No. 3, June 1997, pp. 284-293.
IEEE Top Reference. 0205 BibRef

Shechter, G., Devernay, F., Coste-Maniere, E., Quyyumi, A., McVeigh, E.R.,
Three-dimensional motion tracking of coronary arteries in biplane cineangiograms,
MedImg(22), No. 4, April 2003, pp. 493-503.
IEEE Abstract. IEEE Top Reference. 0306 BibRef

Frangi, A.F., Laclaustra, M., Lamata, P.,
A registration-based approach to quantify flow-mediated dilation (FMD) of the brachial artery in ultrasound image sequences,
MedImg(22), No. 11, November 2003, pp. 1458-1469.
IEEE Abstract. IEEE Top Reference. 0311 BibRef

Yeh, C.K., Ferrara, K.W., Kruse, D.E.,
High-Resolution Functional Vascular Assessment With Ultrasound,
MedImg(23), No. 10, October 2004, pp. 1263-1275.
IEEE Abstract. IEEE Top Reference. 0410 BibRef

Maurice, R.L., Ohayon, J., Fretigny, Y., Bertrand, M., Soulez, G., Cloutier, G.,
Noninvasive Vascular Elastography: Theoretical Framework,
MedImg(23), No. 2, February 2004, pp. 164-180.
IEEE Abstract. IEEE Top Reference. 0403 BibRef

Koh, T.S., Wu, X.Y., Cheong, L.H., Lim, C.C.T.,
Assessment of perfusion by dynamic contrast-enhanced imaging using a deconvolution approach based on regression and singular value decomposition,
MedImg(23), No. 12, December 2004, pp. 1532-1542.
IEEE Abstract. IEEE Top Reference. 0412Blood flow into tissues. BibRef

Glor, F.P., Ariff, B.B., Hughes, A.D., Verdonck, P.R., Thom, S.A.M.G., Barratt, D.C., Xu, X.Y.,
Operator Dependence of 3-D Ultrasound-Based Computational Fluid Dynamics for the Carotid Bifurcation,
MedImg(24), No. 4, April 2005, pp. 451-456.
IEEE Abstract. IEEE Top Reference. 0501 BibRef

Niederhauser, J.J., Jaeger, M., Lemor, R., Weber, P., Frenz, M.,
Combined Ultrasound and Optoacoustic System for Real-Time High-Contrast Vascular Imaging in Vivo,
MedImg(24), No. 4, April 2005, pp. 436-440.
IEEE Abstract. IEEE Top Reference. 0501 BibRef

Shechter, G., Shechter, B., Resar, J.R., Beyar, R.,
Prospective Motion Correction of X-Ray Images for Coronary Interventions,
MedImg(24), No. 4, April 2005, pp. 441-450.
IEEE Abstract. IEEE Top Reference. 0501 BibRef

Cebral, J.R., Lohner, R.,
Efficient Simulation of Blood Flow Past Complex Endovascular Devices Using an Adaptive Embedding Technique,
MedImg(24), No. 4, April 2005, pp. 468-476.
IEEE Abstract. IEEE Top Reference. 0501 BibRef

Rhode, K.S., Lambrou, T., Hawkes, D.J., Seifalian, A.M.,
Novel Approaches to the Measurement of Arterial Blood Flow From Dynamic Digital X-ray Images,
MedImg(24), No. 4, April 2005, pp. 500-513.
IEEE Abstract. IEEE Top Reference. 0501 BibRef

Eden, E., Waisman, D., Rudzsky, M., Bitterman, H., Brod, V., Rivlin, E.,
An Automated Method for Analysis of Flow Characteristics of Circulating Particles From In vivo Video Microscopy,
MedImg(24), No. 8, August 2005, pp. 1011-1024.
WWW Version. 0508 BibRef

Ford, M.D., Stuhne, G.R., Nikolov, H.N., Habets, D.F., Lownie, S.P., Holdsworth, D.W., Steinman, D.A.,
Virtual angiography for visualization and validation of computational models of aneurysm hemodynamics,
MedImg(24), No. 12, December 2005, pp. 1586-1592.
WWW Version. 0601 BibRef

Güler, I.[Inan], Übeyli, E.D.[Elif Derya],
A recurrent neural network classifier for Doppler ultrasound blood flow signals,
PRL(27), No. 13, 1 October 2006, pp. 1560-1571.
WWW Version. Recurrent neural networks; Levenberg-Marquardt algorithm; Discrete wavelet transform; Doppler signal; Ophthalmic artery; Internal carotid artery 0606 BibRef

Wu, W.C., Mazaheri, Y., Wong, E.C.,
The Effects of Flow Dispersion and Cardiac Pulsation in Arterial Spin Labeling,
MedImg(26), No. 1, January 2007, pp. 84-92.
WWW Version. 0701 BibRef

Le, T.M., Paul, J.S., Al-Nashash, H., Tan, A., Luft, A.R., Sheu, F.S., Ong, S.H.,
New Insights into Image Processing of Cortical Blood Flow Monitors Using Laser Speckle Imaging,
MedImg(26), No. 6, June 2007, pp. 833-842.
WWW Version. 0706 BibRef

Tan, Y.K., Liu, W.Z., Yew, Y.S., Ong, S.H., Paul, J.S.,
Speckle image analysis of cortical blood flow and perfusion using temporally derived contrasts,
ICIP04(V: 3323-3326).
WWW Version. 0505 BibRef

Wu, W.C., Buxton, R.B., Wong, E.C.,
Vascular Space Occupancy Weighted Imaging With Control of Residual Blood Signal and Higher Contrast-to-Noise Ratio,
MedImg(26), No. 10, October 2007, pp. 1319-1327.
WWW Version. 0711 BibRef

Yakhot, A., Anor, T., G., E.[Em_Karniadakis,],
A Reconstruction Method for Gappy and Noisy Arterial Flow Data,
MedImg(26), No. 12, December 2007, pp. 1681-1697.
WWW Version. 0712 BibRef


Hoyer, K., Holzner, M., Guala, M., Kinzelbach, W.,
Simultaneous 3D-flow field and compliant wall measurements in an abdominal aortic aneurysm flow using scanning-PTV,
IEVM06(xx-yy).
PDF Version. 0609 BibRef

Chekmenev, S.Y.[Sergey Y.], Farag, A.A.[Aly A.], Essock, E.A.[Edward A.],
Multiresolution Approach for Non-Contact Measurements of Arterial Pulse using Thermal Imaging,
OTCBVS06(129).
WWW Version. 0609 BibRef

Sun, N.[Nanfei], Garbey, M.[Marc], Merla, A.[Arcangelo], Pavlidis, I.[Ioannis],
Imaging the Cardiovascular Pulse,
CVPR05(II: 416-421).
WWW Version. 0507 BibRef

Deneux, T.[Thomas], Vanzetta, I.[Ivo], Masson, G.[Guillaume], Faugeras, O.D.[Olivier D.],
Cerebral blood flow recorded at high sensitivity in two dimensions using high resolution optical imaging,
INRIARR-5759, 2005.
HTML Version. BibRef 0500

Hamou, A.K., El-Sakka, M.R.,
Blood flow generation in b-mode ultrasound images of the carotidartery,
ICIP04(V: 2945-2948).
WWW Version. 0505 BibRef

Garbey, M., Merla, A., Pavlidis, I.,
Estimation of blood flow speed and vessel location from thermal video,
CVPR04(I: 356-363).
IEEE Abstract. IEEE Top Reference. 0408 BibRef

Chapter on Medical Applications, CAT, MRI, Ultrasound, Heart Models, Brain Models continues in
Heart Analysis, ECG, Electrocardiogram .


Last update:Jun 25, 2008 at 13:37:57