20.11 Medical Applications -- Magnetic Resonance Imaging, MRI

Chapter Contents (Back)
MRI. Magnetic Resonance. See also Magnetic Resonance Imaging Systems, Hardware Implementations.

Liang, Z.P.[Zhi-Pei], Lauterbur, P.C.,
A generalized series approach to MR spectroscopic imaging,
MedImg(10), No. 2, June 1991, pp. 132-137.
IEEE Top Reference. This is the work that led to the 2003 Nobel Prize for Lauterbur. BibRef 9106

Liang, Z.P.[Zhi-Pei], Lauterbur, P.C.,
An efficient method for dynamic magnetic resonance imaging,
MedImg(13), No. 4, December 1994, pp. 677-686.
IEEE Top Reference. BibRef 9412

Hyslop, W.B., Woods, R.K., Lauterbur, P.C.,
Four-dimensional spectral-spatial imaging using projection reconstruction,
MedImg(14), No. 2, June 1995, pp. 374 -383.
IEEE Top Reference. BibRef 9506

Sebastiani, G., Godtliebsen, F., Jones, R.A., Haraldseth, O., Muller, T.B., Rinck, P.A.,
Analysis of dynamic magnetic resonance images,
MedImg(15), No. 3, June 1996, pp. 268-277.
IEEE Top Reference. 0203
BibRef
And: Correction: MedImg(16), No. 1, February 1997, pp. 123-124.
IEEE Top Reference. 0205
BibRef

Dellepiane, S.G., Regazzoni, C., Serpico, S.B., Vernazza, G.L.,
Extension of IBIS for 3D Organ Recognition in NMR Multislices,
PRL(8), 1988, pp. 65-72. BibRef 8800

Menhardt, W., Schmidt, K.H.,
Computer Vision on Magnetic Resonance Images,
PRL(8), 1988, pp. 73-85. BibRef 8800

Spaniol, J., Belmont, M.R., Summers, I.R., Vennart, W.,
Generalized Multiresolution Analysis of Magnetic-Resonance Images,
IVC(12), No. 9, November 1994, pp. 601-607.
WWW Version. BibRef 9411

Sarty, G.E.,
Natural K-Plane Coordinate Reconstruction Method for Magnetic Resonance Imaging: Mathematical Foundations,
IJIST(8), No. 6, 1997, pp. 519-528. 9712
BibRef

Sled, J.G., Zijdenbos, A.P., Evans, A.C.,
A Nonparametric Method for Automatic Correction of Intensity Nonuniformity in MRI Data,
MedImg(17), No. 1, February 1998, pp. 87-97.
IEEE Top Reference. 9806
BibRef

Qian, W., Li, H.D., Kallergi, M., Song, D.S., Clarke, L.P.,
Adaptive Neural Network for Nuclear Medicine Image Restoration,
VLSIVideo(18), No. 3, April 1998, pp. 297-315. 9806
BibRef

Nicholl, P.N., Millar, R.J.,
Feature Directed Spiral Coding of Magnetic Resonance Images,
VISP(145), No. 2, April 1998, pp. 131-136. 9806
BibRef
Earlier: A2, A1:
MR image compression by spiral coding,
ICIP94(II: 356-360).
IEEE DOI Link 9411
BibRef

Brinkmann, B.H., Manduca, A., Robb, R.A.,
Optimized Homomorphic Unsharp Masking for MR Grayscale Inhomogeneity Correction,
MedImg(17), No. 2, April 1998, pp. 161-171.
IEEE Top Reference. 9808
BibRef

Manduca, A., Muthupillai, R., Rossman, P.J., Greenleaf, J.F., Ehman, R.L.,
Local wavelength estimation for magnetic resonance elastography,
ICIP96(III: 527-530).
IEEE DOI Link 9610
BibRef

Greensite, F.,
Measure theoretic imaging, with an example employing magnetic resonance input,
MVA(1), No. 3, 1988, pp. 169-174. BibRef 8800

Rybicki, F.J., Patz, S., Hrovat, M.I., Pulyer, Y.M.,
Reconstruction algorithm for novel ultrafast magnetic resonance imaging,
IJIST(10), No. 3, 1999, pp. 209-215. BibRef 9900

Patz, S., Hrovat, M.I., Pulyer, Y.M., Rybicki, F.J.,
Novel encoding technology for ultrafast MRI in a limited spatial region,
IJIST(10), No. 3, 1999, pp. 216-224. BibRef 9900

Sera, I.[Igor], Macura, S.[Slobodan],
Excitation of complex profiles by CARVE sequence: Accounting for spectral dispersion and relaxation,
IJIST(10), No. 3, 1999, pp. 225-241. BibRef 9900

Hess, C.P.[Christopher P.], Liang, Z.P.[Zhi-Pei], Lauterbur, P.C.[Paul C.],
Maximum cross-entropy generalized series reconstruction,
IJIST(10), No. 3, 1999, pp. 258-265. BibRef 9900
Earlier: A1, A2, Add Webb, A.G., A3: ICIP98(I: 19-23).
IEEE DOI Link 9810
MRI. BibRef

Sijbers, J., den Dekker, A.J., Raman, E., van Dyck, D.,
Parameter estimation from magnitude MR images,
IJIST(10), No. 2, 1999, pp. 109-114. BibRef 9900

Petersson, J.S., Christoffersson, J.O.,
Multidimensional k-space model for analysis of flow-related phenomena in MR imaging,
IJIST(10), No. 2, 1999, pp. 115-127. BibRef 9900

Kerwin, W.S., Prince, J.L.,
Tracking MR tag surfaces using a spatiotemporal filter and interpolator,
IJIST(10), No. 2, 1999, pp. 128-142. BibRef 9900
Earlier:
MR tag surface tracking using a spatio-temporal filter/interpolator,
ICIP98(I: 699-703).
IEEE DOI Link 9810
BibRef

Panych, L.P.[Lawrence P.], Zientara, G.P.[Gary P.], Jolesz, F.A.[Ferenc A.],
MR image encoding by spatially selective RF excitation: An analysis using linear response models,
IJIST(10), No. 2, 1999, pp. 143-150. BibRef 9900

Zientara, G.P.[Gary P.], Panych, L.P.[Lawrence P.], Jolesz, F.A.[Ferenc A.],
Near-optimal spatial encoding for dynamically adaptive MRI: Mathematical principles and computational methods,
IJIST(10), No. 2, 1999, pp. 151-165. BibRef 9900

Hoge, W.S., Miller, E.L., Lev-Ari, H., Brooks, D.H., Karl, W.C., Panych, L.P.,
An efficient region of interest acquisition method for dynamic magnetic resonance imaging,
IP(10), No. 7, July 2001, pp. 1118-1128.
IEEE DOI Link 0108
BibRef

Panych, L.P.,
Theoretical comparison of Fourier and wavelet encoding in magnetic resonance imaging,
MedImg(15), No. 2, April 1996, pp. 141-153.
IEEE Top Reference. 0203
BibRef

Wang, Y.M.[Yuan-Mei], Zhao, X.D.[Xiao-Dong],
An iterative method for maximum entropy regularization reconstruction in MRI,
IJIST(10), No. 6, 1999, pp. 427-431. 0003
BibRef

Reczko, M., Karras, D.A., Mertzios, B.G., Graveron-Demilly, D., van Ormondt, D.,
Improved MR image reconstruction from sparsely sampled scans based on neural networks,
PRL(22), No. 1, January 2001, pp. 35-46.
Elsevier DOI Link 0105
BibRef

Barone, P.[Piero], Sebastiani, G.[Giovanni],
Solving an Inverse Diffusion Problem for Magnetic Resonance Dosimetry by a Fast Regularization Method,
RealTimeImg(7), No. 1, February 2001, pp. 21-29.
WWW Version. 0106
BibRef

Harshbarger, T.B., Twieg, D.B.,
Iterative reconstruction of single-shot spiral MRI with off resonance,
MedImg(18), No. 3, March 1999, pp. 196-205.
IEEE Top Reference. 0110
BibRef

Twieg, D.B., Reeves, S.J.,
Basic Properties of SS-PARSE Parameter Estimates,
MedImg(29), No. 5, May 2010, pp. 1156-1172.
IEEE DOI Link 1006
Single shot parameter assessment by retrieval from signal encoding. From single shot MRI signal. BibRef

Stokely, E.M., Twieg, D.,
Reconstructing magnetic resonance spectroscopic image using spatial domain prior,
ICIP94(III: 6-10).
IEEE DOI Link 9411
BibRef

Schomberg, H.,
Off-resonance correction of MR images,
MedImg(18), No. 6, June 1999, pp. 481-495.
IEEE Top Reference. 0110
BibRef

Midtvik, M., Hovig, I.,
Reversible compression of MR images,
MedImg(18), No. 9, September 1999, pp. 795-800.
IEEE Top Reference. 0110
BibRef

Nyul, L.G., Udupa, J.K., Zhang, X.[Xuan],
New variants of a method of MRI scale standardization,
MedImg(19), No. 2, February 2000, pp. 143-150.
IEEE Top Reference. 0110
BibRef

Gomberg, B.R., Saha, P.K., Song, H.K.[Hee Kwon], Hwang, S.N., Wehrli, F.W.,
Topological analysis of trabecular bone MR images,
MedImg(19), No. 3, March 2000, pp. 166-174.
IEEE Top Reference. 0110
BibRef

Saha, P.K.[Punam K.], Gomberg, B.R.[Bryon R.], Wehrli, F.W.[Felix W.],
Three-dimensional digital topological characterization of cancellous bone architecture,
IJIST(11), No. 1, 2000, pp. 81-90. 0005
BibRef

Wehrli, F.W., Saha, P.K., Gomberg, B.R., Song, H.K.[Hee Kwon],
Noninvasive assessment of bone architecture by magnetic resonance micro-imaging-based virtual bone biopsy,
PIEEE(91), No. 10, October 2003, pp. 1520-1542.
IEEE DOI Link 0310
BibRef

Saha, P.K.[Punam Kumar], Wehrli, F.W.[Felix W.],
A robust method for measuring trabecular bone orientation anisotropy at in vivo resolution using tensor scale,
PR(37), No. 9, September 2004, pp. 1935-1944.
WWW Version. 0407
BibRef

Saha, P.K., Wehrli, F.W.,
Measurement of Trabecular Bone Thickness in the Limited Resolution Regime of In Vivo MRI by Fuzzy Distance Transform,
MedImg(23), No. 1, January 2004, pp. 53-62.
IEEE Abstract. 0403
BibRef

Hwang, S.N.[Scott N.], Wehrli, F.W.[Felix W.],
Estimating voxel volume fractions of trabecular bone on the basis of magnetic resonance images acquired in vivo,
IJIST(10), No. 2, 1999, pp. 186-198. BibRef 9900

Yang, W.F.[Wei-Fang], Smith, M.R.,
Using an MRI distortion transfer function to characterize the ghosts in motion-corrupted images,
MedImg(19), No. 6, June 2000, pp. 577-584.
IEEE Top Reference. 0110
BibRef

Liao, J.R.,
Real-time image reconstruction for spiral MRI using fixed-point calculation,
MedImg(19), No. 7, July 2000, pp. 690-698.
IEEE Top Reference. 0110
BibRef

Dale, B., Wendt, M., Duerk, J.L.,
A rapid look-up table method for reconstructing MR images from arbitrary K-space trajectories,
MedImg(20), No. 3, March 2001, pp. 207-217.
IEEE Top Reference. 0110
BibRef

Bookwalter, C.A., Griswold, M.A., Duerk, J.L.,
Multiple Overlapping k-Space Junctions for Investigating Translating Objects (MOJITO),
MedImg(29), No. 2, February 2010, pp. 339-349.
IEEE DOI Link 1002
BibRef

Gao, Y., Reeves, S.J.,
Optimal k-space sampling in MRSI for images with a limited region of support,
MedImg(19), No. 12, December 2000, pp. 1168-1178.
IEEE Top Reference. 0110
BibRef

Ahmed, O.A., Fahmy, M.M.,
NMR signal enhancement via a new time-frequency transform,
MedImg(20), No. 10, October 2001, pp. 1018-1025.
IEEE Top Reference. 0111
BibRef

Alexander, D.C., Pierpaoli, C., Basser, P.J., Gee, J.C.,
Spatial transformations of diffusion tensor magnetic resonance images,
MedImg(20), No. 11, November 2001, pp. 1131-1139.
IEEE Top Reference. 0111
See also Elastic Matching of Diffusion Tensor Images. BibRef

Alexander, D.C.[Daniel C.],
Axon radius measurements in vivo from diffusion MRI: A feasibility study,
MMBIA07(1-8).
IEEE DOI Link 0710
BibRef

Hall, M.G., Alexander, D.C.[Daniel C.],
Convergence and Parameter Choice for Monte-Carlo Simulations of Diffusion MRI,
MedImg(28), No. 9, September 2009, pp. 1354-1364.
IEEE DOI Link 0909
BibRef

Koay, C.G.[Cheng Guan], Chang, L.C.[Lin-Ching], Pierpaoli, C.[Carlo], Basser, P.J.[Peter J.],
Error Propagation Framework for Diffusion Tensor Imaging via Diffusion Tensor Representations,
MedImg(26), No. 8, August 2007, pp. 1017-1034.
IEEE DOI Link 0709
BibRef
And: Erratum: MedImg(26), No. 10, October 2007, pp. 1424-1424.
IEEE DOI Link 0711
BibRef

Tsao, J.,
Extension of finite-support extrapolation using the generalized series model for MR spectroscopic imaging,
MedImg(20), No. 11, November 2001, pp. 1178-1183.
IEEE Top Reference. 0111
BibRef

Gregor, J.[Jens], Rannou, F.R.[Fernando R.],
Three-dimensional support function estimation and application for projection magnetic resonance imaging,
IJIST(12), No. 1, 2002, pp. 43-50.
WWW Version. 0202
BibRef

Noll, D.C.,
Multishot rosette trajectories for spectrally selective MR imaging,
MedImg(16), No. 4, August 1997, pp. 372-377.
IEEE Top Reference. 0205
BibRef

Guillemaud, R., Brady, M.,
Estimating the bias field of MR images,
MedImg(16), No. 3, June 1997, pp. 238-251.
IEEE Top Reference. 0205
BibRef

Schaeffter, T., Grass, M., Proksa, R., Rasche, V.,
Real-time adaptive filtering for projection reconstruction MR fluoroscopy,
MedImg(22), No. 1, January 2003, pp. 75-81.
IEEE Top Reference. 0304
BibRef

Sutton, B.P., Noll, D.C., Fessler, J.A.,
Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities,
MedImg(22), No. 2, February 2003, pp. 178-188.
IEEE Top Reference. 0304
BibRef

Noll, D.C., Fessler, J.A., Sutton, B.P.,
Conjugate Phase MRI Reconstruction With Spatially Variant Sample Density Correction,
MedImg(24), No. 3, March 2005, pp. 325-336.
IEEE Abstract. 0501
BibRef

Funai, A.K., Fessler, J.A., Yeo, D.T.B., Olafsson, V.T., Noll, D.C.,
Regularized Field Map Estimation in MRI,
MedImg(27), No. 10, October 2008, pp. 1484-1494.
IEEE DOI Link 0810
BibRef

Grissom, W.A., Xu, D., Kerr, A.B., Fessler, J.A., Noll, D.C.,
Fast Large-Tip-Angle Multidimensional and Parallel RF Pulse Design in MRI,
MedImg(28), No. 10, October 2009, pp. 1548-1559.
IEEE DOI Link 0910
BibRef

Fessler, J.A.,
Model-Based Image Reconstruction for MRI,
SPMag(27), No. 4, 2010, pp. 81-89.
IEEE DOI Link 1007
BibRef

Mekle, R., Laine, A.F., Wu, E.X.,
Combined MR data acquisition of multicontrast images using variable acquisition parameters and K -space data sharing,
MedImg(22), No. 7, July 2003, pp. 806-823.
IEEE Abstract. 0308
BibRef

Fatouraee, N., Amini, A.A.,
Regularization of flow streamlines in multislice phase-contrast MR imaging,
MedImg(22), No. 6, June 2003, pp. 699-709.
IEEE Abstract. 0308
BibRef

Feng, H.H.[Han-Hua], Gu, H.[Hong], Silbersweig, D., Stern, E., Yang, Y.H.[Yi-Hong],
Single-shot MR imaging using trapezoidal-gradient-based Lissajous trajectories,
MedImg(22), No. 8, August 2003, pp. 925-932.
IEEE Abstract. 0308
BibRef

Ozturk, C., Derbyshire, J.A., McVeigh, E.R.M.,
Estimating motion from MRI data,
PIEEE(91), No. 10, October 2003, pp. 1627-1648.
IEEE DOI Link 0310
BibRef

Netsch, T., van Muiswinkel, A.,
Quantitative Evaluation of Image-Based Distortion Correction in Diffusion Tensor Imaging,
MedImg(23), No. 7, July 2004, pp. 789-798.
IEEE Abstract. 0407
BibRef

Ulloa, J.L., Guarini, M., Guesalaga, A., Irarrazaval, P.,
Chebyshev Series for Designing RF Pulses Employing an Optimal Control Approach,
MedImg(23), No. 11, November 2004, pp. 1445-1452.
IEEE Abstract. 0411
MRI images. BibRef

Irarrazaval, P.[Pablo],
Sampling Less and Reconstructing More for Magnetic Resonance Imaging,
PSIVT07(3).
Springer DOI Link 0712
BibRef

Prieto, C.[Claudia], Guarini, M.[Marcelo], Hajnal, J.[Joseph], Irarrazaval, P.[Pablo],
Motion Estimation Applied to Reconstruct Undersampled Dynamic MRI,
PSIVT07(522-532).
Springer DOI Link 0712
BibRef

van Houten, E.E.W., Doyley, M.M., Kennedy, F.E., Paulsen, K.D., Weaver, J.B.,
A Three-Parameter Mechanical Property Reconstruction Method for MR-Based Elastic Property Imaging,
MedImg(24), No. 3, March 2005, pp. 311-324.
IEEE Abstract. 0501
BibRef

Doyley, M.M., van Houten, E.E., Weaver, J.B., Poplack, S.P., Duncan, L., Kennedy, F.E., Paulsen, K.D.,
Shear Modulus Estimation Using Parallelized Partial Volumetric Reconstruction,
MedImg(23), No. 11, November 2004, pp. 1404-1416.
IEEE Abstract. 0411
MRI application. BibRef

Perrinez, P.R., Kennedy, F.E., van Houten, E.E.W., Weaver, J.B., Paulsen, K.D.,
Magnetic Resonance Poroelastography: An Algorithm for Estimating the Mechanical Properties of Fluid-Saturated Soft Tissues,
MedImg(29), No. 3, March 2010, pp. 746-755.
IEEE DOI Link 1003
BibRef

Weaver, J.B., Healy, Jr., D.M.,
Acquisition of the Karhunen-Loeve expansion to reduce MR imaging times,
ICIP94(III: 35-39).
IEEE DOI Link 9411
BibRef

Twellmann, T., Lichte, O., Nattkemper, T.W.,
An Adaptive Tissue Characterization Network for Model-Free Visualization of Dynamic Contrast-Enhanced Magnetic Resonance Image Data,
MedImg(24), No. 10, October 2005, pp. 1256-1266.
IEEE DOI Link 0510
BibRef

Brown, T.R.[Truman R.], Ochs, M.F.[Michael F.], Rooney, W.D.[William D.], Stoyanova, R.S.[Radka S.], Li, X.[Xin], Springer, Jr., C.S.[Charles S.],
Bayesian image decomposition applied to relaxographic imaging,
IJIST(15), No. 1, 2005, pp. 2-9.
WWW Version. 0507
MRI technique to image tissue. BibRef

Matter, N.I., Scott, G.C., Grafendorfer, T., Macovski, A., Conolly, S.M.,
Rapid Polarizing Field Cycling in Magnetic Resonance Imaging,
MedImg(25), No. 1, January 2006, pp. 84-93.
IEEE DOI Link 0601
BibRef

Ebihara, S., Yamamoto, T.,
Resonance Analysis of a Circular Dipole Array Antenna in Cylindrically Layered Media for Directional Borehole Radar,
GeoRS(44), No. 1, January 2006, pp. 22-31.
IEEE DOI Link 0601
BibRef

Pennec, X.[Xavier], Fillard, P.[Pierre], Ayache, N.J.[Nicholas J.],
A Riemannian Framework for Tensor Computing,
IJCV(66), No. 1, January 2006, pp. 41-66.
Springer DOI Link 0601
BibRef

Pennec, X.[Xavier],
Statistical Computing on Manifolds: From Riemannian Geometry to Computational Anatomy,
ETVC08(347-386).
Springer DOI Link 0811
BibRef

Fillard, P.[Pierre], Pennec, X.[Xavier], Arsigny, V., Ayache, N.J.[Nicholas J.],
Clinical DT-MRI Estimation, Smoothing, and Fiber Tracking With Log-Euclidean Metrics,
MedImg(26), No. 11, November 2007, pp. 1472-1482.
IEEE DOI Link 0709
BibRef

Hokland, S.L., Pedersen, M., Salomir, R., Quesson, B., Stodkilde-Jorgensen, H., Moonen, C.T.W.,
MRI-Guided Focused Ultrasound: Methodology and Applications,
MedImg(25), No. 6, June 2006, pp. 723-731.
IEEE DOI Link 0606
BibRef

Tisdall, M.D., Atkins, M.S.,
Using Human and Model Performance to Compare MRI Reconstructions,
MedImg(25), No. 11, November 2006, pp. 1510-1517.
IEEE DOI Link 0611
BibRef

Eggers, H., Knopp, T., Potts, D.,
Field Inhomogeneity Correction Based on Gridding Reconstruction for Magnetic Resonance Imaging,
MedImg(26), No. 3, March 2007, pp. 374-384.
IEEE DOI Link 0703
BibRef

Verma, R.[Ragini], Khurd, P.[Parmeshwar], Davatzikos, C.[Christos],
On Analyzing Diffusion Tensor Images by Identifying Manifold Structure Using Isomaps,
MedImg(26), No. 6, June 2007, pp. 772-778.
IEEE DOI Link 0706
BibRef
Earlier: A2, A1, A3:
On Characterizing and Analyzing Diffusion Tensor Images by Learning their Underlying Manifold Structure,
MMBIA06(61).
IEEE DOI Link 0609
BibRef

Batmanghelich, N.K.[Nematollah K.], Verma, R.[Ragini],
On non-linear characterization of tissue abnormality by constructing disease manifolds,
MMBIA08(1-8).
IEEE DOI Link 0806
BibRef

Shin, T., Nielsen, J.F., Nayak, K.S.,
Accelerating Dynamic Spiral MRI by Algebraic Reconstruction From Undersampled t Space,
MedImg(26), No. 7, July 2007, pp. 917-924.
IEEE DOI Link 0707
BibRef

Jacob, M., Zhu, X., Ebel, A., Schuff, N., Liang, Z.P.,
Improved Model-Based Magnetic Resonance Spectroscopic Imaging,
MedImg(26), No. 10, October 2007, pp. 1305-1318.
IEEE DOI Link 0711
BibRef

Jian, B., Vemuri, B.C.[Baba C.],
A Unified Computational Framework for Deconvolution to Reconstruct Multiple Fibers From Diffusion Weighted MRI,
MedImg(26), No. 11, November 2007, pp. 1464-1471.
IEEE DOI Link 0709
BibRef

Barmpoutis, A.[Angelos], Vemuri, B.C.[Baba C.],
Information Theoretic Methods for Diffusion-Weighted MRI Analysis,
ETVC08(327-346).
Springer DOI Link 0811
BibRef

Barmpoutis, A.[Angelos], Vemuri, B.C.[Baba C.], Forder, J.R.[John R.],
Robust Tensor Splines for Approximation of Diffusion Tensor MRI Data,
MMBIA06(86).
IEEE DOI Link 0609
BibRef

Kumar, R.[Ritwik], Barmpoutis, A.[Angelos], Vemuri, B.C.[Baba C.], Carney, P.R.[Paul R.], Mareci, T.H.[Thomas H.],
Multi-fiber reconstruction from DW-MRI using a continuous mixture of von Mises-Fisher distributions,
MMBIA08(1-8).
IEEE DOI Link 0806
BibRef

Felfoul, O., Mathieu, J.B., Beaudoin, G., Martel, S.,
In Vivo MR-Tracking Based on Magnetic Signature Selective Excitation,
MedImg(27), No. 1, January 2008, pp. 28-35.
IEEE DOI Link 0712
BibRef

Larson, P.E.Z., Gurney, P.T., Nishimura, D.G.,
Anisotropic Field-of-Views in Radial Imaging,
MedImg(27), No. 1, January 2008, pp. 47-57.
IEEE DOI Link 0712
E.G. projection reconstruction in MRI. Apply to more arbitrary FoV shapes. BibRef

Sinkus, R., Tanter, M., Bercoff, J., Siegmann, K., Pernot, M., Athanasiou, A., Fink, M.,
Potential of MRI and Ultrasound Radiation Force in Elastography: Applications to Diagnosis and Therapy,
PIEEE(96), No. 3, March 2008, pp. 490-499.
IEEE DOI Link 0804
See also NIL. BibRef

Deffieux, T., Montaldo, G., Tanter, M., Fink, M.,
Shear Wave Spectroscopy for In Vivo Quantification of Human Soft Tissues Visco-Elasticity,
MedImg(28), No. 3, March 2009, pp. 313-322.
IEEE DOI Link 0903
BibRef

Wu, Y.C., Field, A.S., Alexander, A.L.,
Computation of Diffusion Function Measures in q-Space Using Magnetic Resonance Hybrid Diffusion Imaging,
MedImg(27), No. 6, June 2008, pp. 858-865.
IEEE DOI Link 0711
BibRef

Koay, C.G., Nevo, U., Chang, L.C., Pierpaoli, C., Basser, P.J.,
The Elliptical Cone of Uncertainty and Its Normalized Measures in Diffusion Tensor Imaging,
MedImg(27), No. 6, June 2008, pp. 834-846.
IEEE DOI Link 0711
BibRef

Lei, T.H.[Tian-Hu], Wehrli, F.W.[Felix W.],
Magnetic Resonance (MR) Image Analysis: A Statistical Approach,
IJIG(7), No. 1, January 2007, pp. 119-141. 0701
BibRef

Zelinski, A.C., Wald, L.L., Setsompop, K., Goyal, V.K., Adalsteinsson, E.,
Sparsity-Enforced Slice-Selective MRI RF Excitation Pulse Design,
MedImg(27), No. 9, September 2008, pp. 1213-1229.
IEEE DOI Link 0809
BibRef

Jones, D.K.,
Tractography Gone Wild: Probabilistic Fibre Tracking Using the Wild Bootstrap With Diffusion Tensor MRI,
MedImg(27), No. 9, September 2008, pp. 1268-1274.
IEEE DOI Link 0809
BibRef

Yeh, C.H., Cho, K.H., Lin, H.C., Wang, J.J., Lin, C.P.,
Reduced Encoding Diffusion Spectrum Imaging Implemented With a Bi-Gaussian Model,
MedImg(27), No. 10, October 2008, pp. 1415-1424.
IEEE DOI Link 0810
Water diffusion spectrum. BibRef

Trzasko, J., Manduca, A.,
Highly Undersampled Magnetic Resonance Image Reconstruction via Homotopic 0-Minimization,
MedImg(28), No. 1, January 2009, pp. 106-121.
IEEE DOI Link 0901
BibRef

Anand, C.K.[Christopher Kumar],
Robust Solvers for Inverse Imaging Problems Using Dense Single-Precision Hardware,
JMIV(33), No. 1, January 2009, pp. xx-yy.
Springer DOI Link 0804
MRI computations. BibRef

Descoteaux, M.[Maxime], Deriche, R.[Rachid], Knosche, T.R., Anwander, A.,
Deterministic and Probabilistic Tractography Based on Complex Fibre Orientation Distributions,
MedImg(28), No. 2, February 2009, pp. 269-286.
IEEE DOI Link 0902
BibRef

Wassermann, D.[Demian], Descoteaux, M.[Maxime], Deriche, R.[Rachid],
Diffusion Maps Segmentation of Magnetic Resonance Q-Ball Imaging,
MMBIA07(1-8).
IEEE DOI Link 0710
BibRef

Haroon, H.A., Morris, D.M., Embleton, K.V., Alexander, D.C., Parker, G.J.M.,
Using the Model-Based Residual Bootstrap to Quantify Uncertainty in Fiber Orientations From Q-Ball Analysis,
MedImg(28), No. 4, April 2009, pp. 535-550.
IEEE DOI Link 0904
BibRef

Seunarine, K.K.[Kiran K.], Cook, P.A., Hall, M.G., Embleton, K.V., Parker, G.J.M., Alexander, D.C.[Daniel C],
Exploiting peak anisotropy for tracking through complex structures,
MMBIA07(1-8).
IEEE DOI Link 0710
Multi-fibre reconstruction techniques, such as Persistent Angular Structure (PAS) MRI or QBall Imaging. BibRef

Li, Y.[Yu], Huang, F.[Feng],
Regionally Optimized Reconstruction for Partially Parallel Imaging in MRI Applications,
MedImg(28), No. 5, May 2009, pp. 687-695.
IEEE DOI Link 0905
BibRef

Commowick, O., Warfield, S.K.[Simon K.],
A Continuous STAPLE for Scalar, Vector, and Tensor Images: An Application to DTI Analysis,
MedImg(28), No. 6, June 2009, pp. 838-846.
IEEE DOI Link 0906
BibRef

Commowick, O., Warfield, S.K.,
Estimation of Inferential Uncertainty in Assessing Expert Segmentation Performance From STAPLE,
MedImg(29), No. 3, March 2010, pp. 771-780.
IEEE DOI Link 1003
BibRef

Kelm, B.M., Menze, B.H., Nix, O., Zechmann, C.M., Hamprecht, F.A.,
Estimating Kinetic Parameter Maps From Dynamic Contrast-Enhanced MRI Using Spatial Prior Knowledge,
MedImg(28), No. 10, October 2009, pp. 1534-1547.
IEEE DOI Link 0910
BibRef

Kwon, O.I., Park, C., Nam, H.S., Woo, E.J., Seo, J.K., Glaser, K.J., Manduca, A., Ehman, R.L.,
Shear Modulus Decomposition Algorithm in Magnetic Resonance Elastography,
MedImg(28), No. 10, October 2009, pp. 1526-1533.
IEEE DOI Link 0910
BibRef

Block, K.T., Uecker, M., Frahm, J.,
Model-Based Iterative Reconstruction for Radial Fast Spin-Echo MRI,
MedImg(28), No. 11, November 2009, pp. 1759-1769.
IEEE DOI Link 0911
BibRef

Zibetti, M.V.W., de Pierro, A.R.,
A New Distortion Model for Strong Inhomogeneity Problems in Echo-Planar MRI,
MedImg(28), No. 11, November 2009, pp. 1736-1753.
IEEE DOI Link 0911
BibRef

Sorensen, T.S., Atkinson, D., Schaeffter, T., Hansen, M.S.[Michael Sass],
Real-Time Reconstruction of Sensitivity Encoded Radial Magnetic Resonance Imaging Using a Graphics Processing Unit,
MedImg(28), No. 12, December 2009, pp. 1974-1985.
IEEE DOI Link 0912
BibRef

Ozkan, K.Ö., Gencer, N.G.,
Low-Frequency Magnetic Subsurface Imaging: Reconstructing Conductivity Images of Biological Tissues via Magnetic Measurements,
MedImg(28), No. 4, April 2009, pp. 564-570.
IEEE DOI Link 0904
BibRef

Knopp, T., Sattel, T.F., Biederer, S., Rahmer, J., Weizenecker, J., Gleich, B., Borgert, J., Buzug, T.M.[Thorsten M.],
Model-Based Reconstruction for Magnetic Particle Imaging,
MedImg(29), No. 1, January 2010, pp. 12-18.
IEEE DOI Link 1001
BibRef

Maitra, R., Riddles, J.J.,
Synthetic Magnetic Resonance Imaging Revisited,
MedImg(29), No. 3, March 2010, pp. 895-902.
IEEE DOI Link 1003
BibRef

Liu, C., Zhang, J., Moseley, M.E.,
Auto-Calibrated Parallel Imaging Reconstruction for Arbitrary Trajectories Using k-Space Sparse Matrices (kSPA),
MedImg(29), No. 3, March 2010, pp. 950-959.
IEEE DOI Link 1003
MRI accelerated by multiple receiving coils. Construction. BibRef

Eslami, R., Jacob, M.,
Robust Reconstruction of MRSI Data Using a Sparse Spectral Model and High Resolution MRI Priors,
MedImg(29), No. 6, June 2010, pp. 1297-1309.
IEEE DOI Link 1007
BibRef

Kornak, J., Young, K., Soher, B.J., Maudsley, A.A.,
Bayesian k-Space-Time Reconstruction of MR Spectroscopic Imaging for Enhanced Resolution,
MedImg(29), No. 7, July 2010, pp. 1333-1350.
IEEE DOI Link 1007
BibRef
And: Correction: MedImg(29), No. 9, September 2010, pp. 1697-1697.
IEEE DOI Link 1003
BibRef

Testud, F., Splitthoff, D.N., Speck, O., Hennig, J., Zaitsev, M.,
Direct Magnetic Field Estimation Based on Echo Planar Raw Data,
MedImg(29), No. 7, July 2010, pp. 1401-1411.
IEEE DOI Link 1007
BibRef

Schultz, G., Weber, H., Gallichan, D., Witschey, W.R.T., Welz, A.M., Cocosco, C.A., Hennig, J., Zaitsev, M.,
Radial Imaging With Multipolar Magnetic Encoding Fields,
MedImg(30), No. 12, December 2011, pp. 2134-2145.
IEEE DOI Link 1112
BibRef

Yeh, F.C., Wedeen, V.J., Tseng, W.Y.I.,
Generalized q-Sampling Imaging,
MedImg(29), No. 9, September 2010, pp. 1626-1635.
IEEE DOI Link 1003
for MRI analysis. BibRef

Florack, L.[Luc], Balmashnova, E.[Evgeniya], Astola, L.[Laura], Brunenberg, E.[Ellen],
A New Tensorial Framework for Single-Shell High Angular Resolution Diffusion Imaging,
JMIV(38), No. 3, November 2010, pp. 171-181.
WWW Version. 1011
BibRef

Astola, L.[Laura], Jalba, A.[Andrei], Balmashnova, E.[Evgeniya], Florack, L.[Luc],
Finsler Streamline Tracking with Single Tensor Orientation Distribution Function for High Angular Resolution Diffusion Imaging,
JMIV(41), No. 3, November 2011, pp. 170-181.
WWW Version. 1110
BibRef

Tapia, E.[Ernesto],
A note on the computation of high-dimensional integral images,
PRL(32), No. 2, 15 January 2011, pp. 197-201.
Elsevier DOI Link
WWW Version. 1101
Integral image; Haar-based features; High-dimensional image; Mobius inversion formula; Neuroimaging BibRef

Saritas, E.U., Lee, J.H., Nishimura, D.G.,
SNR Dependence of Optimal Parameters for Apparent Diffusion Coefficient Measurements,
MedImg(30), No. 2, February 2011, pp. 424-437.
IEEE DOI Link 1102
DWI - diffusion weighted imaging BibRef

Ye, X., Chen, Y., Lin, W., Huang, F.,
Fast MR Image Reconstruction for Partially Parallel Imaging With Arbitrary k-Space Trajectories,
MedImg(30), No. 3, March 2011, pp. 575-585.
IEEE DOI Link 1103
BibRef

Ramani, S., Fessler, J.A.,
Parallel MR Image Reconstruction Using Augmented Lagrangian Methods,
MedImg(30), No. 3, March 2011, pp. 694-706.
IEEE DOI Link 1103
BibRef

Liu, Y., Chen, L., Yu, Y.,
Diffusion Kurtosis Imaging Based on Adaptive Spherical Integral,
SPLetters(18), No. 4, April 2011, pp. 243-246.
IEEE DOI Link 1103
BibRef

Mace, E., Cohen, I., Montaldo, G., Miles, R., Fink, M., Tanter, M.,
In Vivo Mapping of Brain Elasticity in Small Animals Using Shear Wave Imaging,
MedImg(30), No. 3, March 2011, pp. 550-558.
IEEE DOI Link 1103
BibRef

De Wall, R.J., Varghese, T., Madsen, E.L.,
Shear Wave Velocity Imaging Using Transient Electrode Perturbation: Phantom and ex vivo Validation,
MedImg(30), No. 3, March 2011, pp. 666-678.
IEEE DOI Link 1103
BibRef

Seeger, M.W.[Matthias W.], Nickisch, H.[Hannes],
Large Scale Bayesian Inference And Experimental Design For Sparse Linear Models,
SIIMS(4), No. 1, 2011, pp. 166-199.
WWW Version.
WWW Version. sparse linear model; sparsity prior; experimental design; sampling optimization; image acquisition; variational approximate inference; Bayesian statistics; compressive sensing; sparse reconstruction; magnetic resonance imaging BibRef 1100

Astola, L.[Laura], Florack, L.M.J.[Luc M.J.],
Finsler Geometry on Higher Order Tensor Fields and Applications to High Angular Resolution Diffusion Imaging,
IJCV(92), No. 3, May 2011, pp. 325-336.
WWW Version. 1103
BibRef
Earlier: SSVM09(224-234).
Springer DOI Link 0906
BibRef

Haldar, J.P., Hernando, D., Liang, Z.P.,
Compressed-Sensing MRI With Random Encoding,
MedImg(30), No. 4, April 2011, pp. 893-903.
IEEE DOI Link 1104
BibRef

Ravishankar, S., Bresler, Y.,
MR Image Reconstruction From Highly Undersampled k-Space Data by Dictionary Learning,
MedImg(30), No. 5, May 2011, pp. 1028-1041.
IEEE DOI Link 1105
BibRef

Lingala, S.G., Hu, Y., di Bella, E.V.R.[Edward V. R.], Jacob, M.,
Accelerated Dynamic MRI Exploiting Sparsity and Low-Rank Structure: k-t SLR,
MedImg(30), No. 5, May 2011, pp. 1042-1054.
IEEE DOI Link 1105
BibRef

Hu, Y., Lingala, S.G., Jacob, M.,
A Fast Majorize-Minimize Algorithm for the Recovery of Sparse and Low-Rank Matrices,
IP(21), No. 2, February 2012, pp. 742-753.
IEEE DOI Link 1201
BibRef

Ye, X., Chen, Y., Huang, F.,
Computational Acceleration for MR Image Reconstruction in Partially Parallel Imaging,
MedImg(30), No. 5, May 2011, pp. 1055-1063.
IEEE DOI Link 1105
BibRef

Montefusco, L.B., Lazzaro, D., Papi, S., Guerrini, C.,
A Fast Compressed Sensing Approach to 3D MR Image Reconstruction,
MedImg(30), No. 5, May 2011, pp. 1064-1075.
IEEE DOI Link 1105
BibRef

Michailovich, O.V., Rathi, Y., Dolui, S.,
Spatially Regularized Compressed Sensing for High Angular Resolution Diffusion Imaging,
MedImg(30), No. 5, May 2011, pp. 1100-1115.
IEEE DOI Link 1105
BibRef

Ramirez, L., Prieto, C., Sing-Long, C., Uribe, S., Batchelor, P., Tejos, C., Irarrazaval, P.,
TRIO a Technique for Reconstruction Using Intensity Order: Application to Undersampled MRI,
MedImg(30), No. 8, August 2011, pp. 1566-1576.
IEEE DOI Link 1108
BibRef

Guerquin-Kern, M., Haberlin, M., Pruessmann, K.P., Unser, M.,
A Fast Wavelet-Based Reconstruction Method for Magnetic Resonance Imaging,
MedImg(30), No. 9, September 2011, pp. 1649-1660.
IEEE DOI Link 1109
BibRef

Huang, J.Z.[Jun-Zhou], Zhang, S.T.[Shao-Ting], Li, H.S.[Hong-Sheng], Metaxas, D.N.[Dimitris N.],
Composite splitting algorithms for convex optimization,
CVIU(115), No. 12, December 2011, pp. 1610-1622.
Elsevier DOI Link
WWW Version. 1111
Convex optimization; Composite splitting; Compressive sensing; MR image reconstruction; Low-rank tensor completion BibRef

Kaden, E., Kruggel, F.,
A Reproducing Kernel Hilbert Space Approach for Q-Ball Imaging,
MedImg(30), No. 11, November 2011, pp. 1877-1886.
IEEE DOI Link 1111
BibRef

Strachota, P.[Pavel], Beneš, M.[Michal], Tintera, J.[Jaroslav],
Towards clinical applicability of the diffusion-based DT-MRI visualization algorithm,
JVCIR(23), No. 2, February 2012, pp. 387-396.
Elsevier DOI Link
WWW Version. 1201
Biomedical magnetic resonance imaging; Diffusion equations; Computational study; Parallel processing; Scientific visualization; Diffusion tensor; Numerical solution; Total variation BibRef


Lu, W.[Wei], Li, T.[Taoran], Atkinson, I.C.[Ian C.], Vaswani, N.[Namrata],
Modified-CS-residual for recursive reconstruction of highly undersampled functional MRI sequences,
ICIP11(2689-2692).
IEEE DOI Link 1201
BibRef

Deng, J.[Jun], Yang, Z.[Zai], Zhang, C.S.[Ci-Shen], Lu, W.M.[Wen-Miao],
Orthonormal expansion l1-minimization for compressed sensing in MRI,
ICIP11(2297-2300).
IEEE DOI Link 1201
BibRef

Zhu, Y.[Yonggui], Chern, I.L.[I-Liang],
Fast Alternating Minimization Method for Compressive Sensing MRI under Wavelet Sparsity and TV Sparsity,
ICIG11(356-361).
IEEE DOI Link 1109
BibRef

Sun, Y.C.[Yuan-Chang], Xin, J.[Jack],
A Recursive Sparse Blind Source Separation Method for Nonnegative and Correlated Data in NMR Spectroscopy,
CAIP11(II: 81-88).
Springer DOI Link 1109
BibRef

Lizarbe, B.[Blanca], Benitez, A.[Ania], Lago, L.[Luis], Sanchez-Montańes, M.[Manuel], López-Larrubia, P.[Pilar], Cerdán, S.[Sebastián],
Intelligent Image Analysis of Diffusion Weighted Data Sets: A New Tool for Functional Imaging,
IWCIA11(9-12).
Springer DOI Link 1105
BibRef

Chinea, A.[Alejandro],
Nonlinear Dynamical Analysis of Magnetic Resonance Spectroscopy Data,
IWCIA11(469-482).
Springer DOI Link 1105
BibRef

Liu, Y.G.[Yu-Gang], Wei, S.M.[Si-Ming], Jiang, Q.[Quan], Yu, Y.Z.[Yi-Zhou],
Reconstructing diffusion kurtosis tensors from sparse noisy measurements,
ICIP10(4185-4188).
IEEE DOI Link 1009
Diffusion kurtosis imaging in MRI BibRef

Aelterman, J.[Jan], Luong, H.Q.[Hiep Quang], Goossens, B.[Bart], Pizurica, A.[Aleksandra], Philips, W.[Wilfried],
Compass: A joint framework for Parallel Imaging and Compressive Sensing in MRI,
ICIP10(1653-1656).
IEEE DOI Link 1009
BibRef

Fan, G.Z.[Guang-Zhe], Wang, Z.[Zhou], Kim, S.B.[Seoung Bum], Temiyasathit, C.[Chivalai],
Classification of High-Resolution NMR Spectra Based on Complex Wavelet Domain Feature Selection and Kernel-Induced Random Forest,
ICISP10(593-600).
Springer DOI Link 1006
BibRef

Krajsek, K.[Kai], Menzel, M.I.[Marion I.], Scharr, H.[Hanno],
Riemannian Bayesian estimation of diffusion tensor images,
ICCV09(2327-2334).
IEEE DOI Link 0909
DT-MRI. BibRef

Chen, Z.L.[Zhao-Lin], Johnston, L., Faggian, N., Kean, M., Zhang, J.X.[Jing-Xin], Egan, G.,
A Multistage Parallel Magnetic Resonance Image Reconstruction Method,
DICTA08(327-334).
IEEE DOI Link 0812
BibRef

McGraw, T.[Tim], Kawai, T.[Takamitsu], Yassine, I.[Inas], Zhu, L.[Lierong],
New Scalar Measures for Diffusion-Weighted MRI Visualization,
ISVC09(I: 934-943).
Springer DOI Link 0911
BibRef

Wang, M.M.[Miao Miao], Ding, X.H.[Xing Hao], Xiao, Q.[Quan], Cai, C.B.[Cong Bo],
Contourlet Based MR Image Reconstruction via Reweighted L1-Minimization,
CISP09(1-3).
IEEE DOI Link 0910
BibRef

Chen, S.S.[Shan-Shan], Li, R.[Ran], Yu, J.[Jie], Wang, H.Z.[Hong-Zhi], Zhang, X.L.[Xue-Long],
Program Algorithm Research of T2 Spectrum in NMR and MATLAB Realization,
CISP09(1-4).
IEEE DOI Link 0910
BibRef

Zhang, Z.M.[Zhen-Min], Peng, L.[Ling], Cai, S.H.[Shu-Hui], Chen, Z.[Zhong],
Signal Reconstruction in Unstable Magnetic Field NMR with Wavelet Analysis,
CISP09(1-4).
IEEE DOI Link 0910
BibRef

Zhao, M.[Min], Zhang, D.L.[Dong-Lai],
The Research of Parallel Magnetic Field Tomography Based on Finite Element Method,
CISP09(1-4).
IEEE DOI Link 0910
BibRef

Ehricke, H.H.[Hans-Heino], Otto, K.M.[Kay M.], Kumar, V.[Vinoid], Klose, U.[Uwe],
Diffusion MRI Tractography of Crossing Fibers by Cone-Beam ODF Regularization,
DAGM09(412-421).
Springer DOI Link 0909
BibRef

Peng, Y.[Yanni], Liu, Q.H.[Qing Huo],
An improved MRI reconstruction method based on table-lookup gridding,
IASP09(9-12).
IEEE DOI Link 0904
BibRef

Baldassarre, L.[Luca], Barla, A.[Annalisa], Gianesin, B.[Barbara], Marinelli, M.[Mauro],
Vector valued regression for iron overload estimation,
ICPR08(1-4).
IEEE DOI Link 0812
Not really MRI, but a magnetic iron detector to analyze body iron levels. BibRef

Tensaouti, F.[Fatima], Delion, M.[Matthieu], Lotterie, J.A.[Jean Albert], Clarisse, P.[Perrine], Berry, I.[Isabelle],
Reproducibility and reliability of the DTI fiber tracking algorithm integrated in the Sisyphe software,
IPTA08(1-5).
IEEE DOI Link 0811
BibRef

Ito, S.[Satoshi], Yamada, Y.[Yoshifumi],
Improvement of spatial resolution in magnetic resonance imaging using quadratic phase modulation,
ICIP09(2497-2500).
IEEE DOI Link 0911
BibRef
Earlier:
Parallel image reconstruction using a single signal in magnetic resonance imaging,
ICIP08(2964-2967).
IEEE DOI Link 0810
BibRef

Malczewski, K.[Krzysztof], Stasinski, R.[Ryszard],
Toeplitz-based iterative image fusion scheme for MRI,
ICIP08(341-344).
IEEE DOI Link 0810
BibRef

Lienemann, K.[Kai], Plötz, T.[Thomas], Fink, G.A.[Gernot A.],
Automatic Classification of NMR Spectra by Ensembles of Local Experts,
SSPR08(790-800).
Springer DOI Link 0812
BibRef

Leow, A.[Alex], Zhu, S.W.[Si-Wei], McMahon, K.[Katie], de Zubicaray, G.I.[Greig I.], Meredith, M.[Matt], Wright, M.[Margie], Thompson, P.[Paul],
Probabilistic multi-tensor estimation using the Tensor Distribution Function,
CVPR08(1-6).
IEEE DOI Link 0806
MRI BibRef

Ma, S.Q.[Shi-Qian], Yin, W.T.[Wo-Tao], Zhang, Y.[Yin], Chakraborty, A.[Amit],
An efficient algorithm for compressed MR imaging using total variation and wavelets,
CVPR08(1-8).
IEEE DOI Link 0806
BibRef

Sepasian, N.[Neda], Vilanova, A.[Anna], Florack, L.M.J.[Luc M.J.], ter Haar Romeny, B.M.,
A ray tracing method for geodesic based tractography in diffusion tensor images,
MMBIA08(1-6).
IEEE DOI Link 0806
BibRef

Savadjiev, P.[Peter], Zucker, S.W.[Steven W.], Siddiqi, K.[Kaleem],
On the Differential Geometry of 3D Flow Patterns: Generalized Helicoids and Diffusion MRI Analysis,
ICCV07(1-8).
IEEE DOI Link 0710
BibRef

Chen, Z.L.[Zhao-Lin], Zhang, J.X.[Jing-Xin], Li, S.P.[Shen-Peng], Chai, L.[Li],
FB Analysis of PMRI and its Application to H-Inf Optimal Sense Reconstruction,
ICIP07(III: 129-132).
IEEE DOI Link 0709
Filter Bank analysis of parallel MRI for image reconstruction. BibRef

Landman, B.[Bennett], Bazin, P.L.[Pierre-Louis], Prince, J.L.[Jerry L.],
Diffusion Tensor Estimation by Maximizing Rician Likelihood,
MMBIA07(1-8).
IEEE DOI Link 0710
BibRef

Merhof, D.[Dorit], Hastreiter, P.[Peter], Soza, G.[Grzegorz], Nimsky, C.[Christopher],
Non-linear Integration of DTI-based Fiber Tracts into Standard 3D MR Data,
VMV04(371-378). 0411
BibRef

Sinha, N.[Neelam], Saranathan, M.[Manojkumar], Ramakrishnan, K.R., Suresh, S.,
Parallel Magnetic Resonance Imaging using Neural Networks,
ICIP07(III: 149-152).
IEEE DOI Link 0709
BibRef

Otazo, R.[Ricardo], Jordan, R.[Ramiro], Lin, F.H.[Fa-Hsuan], Posse, S.[Stefan],
Superresolution Parallel MRI,
ICIP07(III: 153-156).
IEEE DOI Link 0709
BibRef

Mayer, G.S.[Gregory S.], Vrscay, E.R.[Edward R.],
Iterated Fourier Transform Systems: A Method for Frequency Extrapolation,
ICIAR07(728-739).
Springer DOI Link 0708
BibRef

Mayer, G.S.[Gregory S.], Vrscay, E.R.[Edward R.],
Mathematical Analysis of 'Phase Ramping' for Super-Resolution Magnetic Resonance Imaging,
ICIAR06(I: 82-93).
Springer DOI Link 0610
BibRef

Wang, Z.[Zhou], Kim, S.B.[Seoung Bum],
Automatic Alignment of High-Resolution NMR Spectra Using a Bayesian Estimation Approach,
ICPR06(IV: 667-670).
IEEE DOI Link 0609
BibRef

Tschumperle, D., Deriche, R.,
Variational frameworks for DT-MRI estimation, regularization and visualization,
ICCV03(116-121).
IEEE DOI Link 0311
BibRef

Husse, S., Goussard, Y.,
Image Reconstruction in MRI: Regularized Approach by Markov Random Fields,
ICIP03(II: 851-854).
IEEE Abstract. 0312
BibRef

Bardinet, É.[Éric], Malandain, G.[Grégoire],
Fusion of autoradiographies with an MR volume using 2-D and 3-D linear transformations,
INRIARR-4791, Mars 2003.
HTML Version. 0306
BibRef

Roullot, E., Herment, A., Bloch, I., Nikolova, M., Mousseaux, E.,
Regularized Reconstruction of 3d High-resolution Magnetic Resonance Images from Acquisitions of Anisotropically Degraded Resolutions,
ICPR00(Vol III: 346-349).
IEEE DOI Link 0009
BibRef

Fahmy, A., Tewfik, A.H., Kadah, Y.M.,
Robust Estimation of Planar Rigid Body Motion in Magnetic Resonance Imaging,
ICIP00(Vol II: 487-490).
IEEE Abstract. 0008
BibRef

Xu, D.X.[Dong-Xiang], Hwang, J.N.[Jenq-Neng], Yuan, C.[Chun],
A Robust Method of Identifying and Measuring Fibrous Cap in 3D Time-of-Flight MR Image,
ICIP99(II:164-167).
IEEE Abstract. BibRef 9900

Meyer, C.R., Bland, P.H., Pipe, J.,
Retrospective Correction of MRI Amplitude Inhomogeneities,
CVRMed95(XX-YY). BibRef 9500

Palubinskas, G.,
Adaptive Filtering in Magnetic Resonance Images,
ICPR96(III: 523-527).
IEEE DOI Link 9608
(Max-Planck-Inst. of Cognitive Neuroscience, D) BibRef

Reeves, S.J., Hezar, R.,
Selection of observations in magnetic resonance spectroscopic imaging,
ICIP95(I: 641-644).
IEEE DOI Link 9510
BibRef

Cao, Y., Levin, D.N.,
Locally focused magnetic resonance imaging,
ICIP94(III: 30-34).
IEEE DOI Link 9411
BibRef

Hu, X.P.[Xiao-Ping], Parrish, T., Patel, M.,
Novel sampling schemes in magnetic resonance imaging,
ICIP94(III: 15-19).
IEEE DOI Link 9411
BibRef

Plevritis, S.K., Macovski, A.,
Alternative k-space sampling distributions for MR spectroscopic imaging,
ICIP94(III: 11-14).
IEEE DOI Link 9411
BibRef

Chapter on Medical Applications, CAT, MRI, Ultrasound, Heart Models, Brain Models continues in
Magnetic Resonance Imaging Systems, Hardware Implementations .


Last update:Feb 8, 2012 at 11:25:05