20.11.1 Magnetic Resonance Imaging Systems, Hardware Implementations

Chapter Contents (Back)
MRI. Magnetic Resonance. See also Stereoscopic Viewing, Three Dimensional Visualization, Displays, Holography.

BodyViz: Visual Medical Solutions,
2012
WWW Version. Visualization. Vendor, Medical Visualization. 3-D MRI and CT visulaization.

Smith, M.R., Chen, L., Hui, Y., Mathews, T., Yang, J., Zeng, X.,
Alternatives to the Use of the DFT in MRI and Spectroscopic Reconstructions,
IJIST(8), No. 6, 1997, pp. 558-564. 9712
BibRef

Ider, Y.Z., Muftuler, L.T.,
Measurement of AC magnetic field distribution using magnetic resonance imaging,
MedImg(16), No. 5, October 1997, pp. 617-622.
IEEE Top Reference. 0205
BibRef

Koksal, A.[Adnan], Eyuboglu, B.M.[B. Murat], Demirbilek, M.[Mehmet],
A quasi-static analysis for a class of induced-current EIT systems using discrete coils,
MedImg(21), No. 6, June 2002, pp. 688-694.
IEEE Top Reference. 0208
BibRef

Degirmenci, E., Eyuboglu, B.M.,
Image Reconstruction in Magnetic Resonance Conductivity Tensor Imaging (MRCTI),
MedImg(31), No. 3, March 2012, pp. 525-532.
IEEE DOI Link 1203
BibRef

Curiel, L., Chopra, R., Hynynen, K.,
Progress in Multimodality Imaging: Truly Simultaneous Ultrasound and Magnetic Resonance Imaging,
MedImg(26), No. 12, December 2007, pp. 1740-1746.
IEEE DOI Link 0712
BibRef

Mahmood, U., Josephson, L.,
Molecular MR Imaging Probes,
PIEEE(93), No. 4, April 2005, pp. 800-808.
IEEE DOI Link 0504
BibRef

Vukovic, A., Sewell, P., McKirdy, D., Thomas, D., Benson, T.M., Christopoulos, C., Glover, P.,
A Dynamic Vector Model of Microstrip RF Resonators for High-Field MR Imaging,
MedImg(27), No. 6, June 2008, pp. 766-774.
IEEE DOI Link 0711
BibRef

Yuan, J., Wei, J., Shen, G.X.,
A 4-Channel Coil Array Interconnection by Analog Direct Modulation Optical Link for 1.5-T MRI,
MedImg(27), No. 10, October 2008, pp. 1432-1438.
IEEE DOI Link 0810
BibRef

Wang, S., Murphy-Boesch, J., Merkle, H., Koretsky, A.P., Duyn, J.H.,
B_1 Homogenization in MRI by Multilayer Coupled Coils,
MedImg(28), No. 4, April 2009, pp. 551-554.
IEEE DOI Link 0904
BibRef

Goodwill, P.W., Scott, G.C., Stang, P.P., Conolly, S.M.,
Narrowband Magnetic Particle Imaging,
MedImg(28), No. 8, August 2009, pp. 1231-1237.
IEEE DOI Link 0909
BibRef

Goodwill, P.W., Conolly, S.M.,
The X-Space Formulation of the Magnetic Particle Imaging Process: 1-D Signal, Resolution, Bandwidth, SNR, SAR, and Magnetostimulation,
MedImg(29), No. 11, November 2010, pp. 1851-1859.
IEEE DOI Link 1011
BibRef

Goodwill, P.W., Conolly, S.M.,
Multidimensional X-Space Magnetic Particle Imaging,
MedImg(30), No. 9, September 2011, pp. 1581-1590.
IEEE DOI Link 1109
BibRef

Goodwill, P.W., Konkle, J.J., Zheng, B., Saritas, E.U., Conolly, S.T.,
Projection X-Space Magnetic Particle Imaging,
MedImg(31), No. 5, May 2012, pp. 1076-1085.
IEEE DOI Link 1202
BibRef

Zanchi, M.G., Venook, R., Pauly, J.M., Scott, G.C.,
An Optically Coupled System for Quantitative Monitoring of MRI-Induced RF Currents Into Long Conductors,
MedImg(29), No. 1, January 2010, pp. 169-178.
IEEE DOI Link 1001
BibRef

Zanchi, M.G., Stang, P., Kerr, A., Pauly, J.M., Scott, G.C.,
Frequency-Offset Cartesian Feedback for MRI Power Amplifier Linearization,
MedImg(30), No. 2, February 2011, pp. 512-522.
IEEE DOI Link 1102
BibRef

Wu, B., Wang, C., Kelley, D.A.C., Xu, D., Vigneron, D.B., Nelson, S.J., Zhang, X.,
Shielded Microstrip Array for 7T Human MR Imaging,
MedImg(29), No. 1, January 2010, pp. 179-184.
IEEE DOI Link 1001
BibRef

Wu, B., Wang, C., Lu, J., Pang, Y., Nelson, S.J., Vigneron, D.B., Zhang, X.,
Multi-Channel Microstrip Transceiver Arrays Using Harmonics for High Field MR Imaging in Humans,
MedImg(31), No. 2, February 2012, pp. 183-191.
IEEE DOI Link 1202
BibRef

Pang, Y., Zhang, X., Xie, Z., Wang, C., Vigneron, D.B.,
Common-Mode Differential-Mode (CMDM) Method for Double-Nuclear MR Signal Excitation and Reception at Ultrahigh Fields,
MedImg(30), No. 11, November 2011, pp. 1965-1973.
IEEE DOI Link 1111
BibRef

Mager, D., Peter, A., Tin, L.D., Fischer, E., Smith, P.J., Hennig, J., Korvink, J.G.,
An MRI Receiver Coil Produced by Inkjet Printing Directly on to a Flexible Substrate,
MedImg(29), No. 2, February 2010, pp. 482-487.
IEEE DOI Link 1002
BibRef

Webb, A.G.[Andrew G.], Collins, C.M.[Christopher M.],
Parallel transmit and receive technology in high-field magnetic resonance neuroimaging,
IJIST(20), No. 1, March 2010, pp. 2-13.
WWW Version. 1003
BibRef

Ying, L.[Leslie], Liang, Z.P.[Zhi-Pei],
Parallel MRI Using Phased Array Coils,
SPMag(27), No. 4, 2010, pp. 90-98.
IEEE DOI Link 1007
BibRef

Majewski, K., Heid, O., Kluge, T.,
MRI Pulse Sequence Design With First-Order Gradient Moment Nulling in Arbitrary Directions by Solving a Polynomial Program,
MedImg(29), No. 6, June 2010, pp. 1252-1259.
IEEE DOI Link 1007
BibRef

Stuker, F., Baltes, C., Dikaiou, K., Vats, D., Carrara, L., Charbon, E., Ripoll, J., Rudin, M.,
Hybrid Small Animal Imaging System Combining Magnetic Resonance Imaging With Fluorescence Tomography Using Single Photon Avalanche Diode Detectors,
MedImg(30), No. 6, June 2011, pp. 1265-1273.
IEEE DOI Link 1101
BibRef


Garcia-Gomez, J.M.[Juan M.], Robles, M.[Montserrat], van Huffel, S.[Sabine], Juan-Císcar, A.[Alfons],
Modelling of Magnetic Resonance Spectra Using Mixtures for Binned and Truncated Data,
IbPRIA07(II: 266-273).
Springer DOI Link 0706
BibRef

Garnaoui, H.H., Tewfik, A.H.,
Visual masking and the design of magnetic resonance image acquisition,
ICIP95(I: 625-628).
IEEE DOI Link 9510
BibRef

Kadah, Y.M., Tewfik, A.H.,
Theory of true-velocity duplex imaging using a single transducer,
ICIP95(I: 629-632).
IEEE DOI Link 9510
BibRef

Chapter on Medical Applications, CAT, MRI, Ultrasound, Heart Models, Brain Models continues in
Segmentation, Features, Models from Magnetic Resonance Data, MRI .


Last update:May 16, 2012 at 20:31:07