Zoroofi, R.A.,
Sato, Y.,
Tamura, S.,
Naito, H.,
MRI artifact cancellation due to rigid motion in the imaging plane,
MedImg(15), No. 6, December 1996, pp. 768-784.
IEEE Top Reference.
0203
BibRef
Atkinson, D.,
Hill, D.L.G.,
Stoyle, P.N.R.,
Summers, P.E.,
Keevil, S.F.,
Automatic Correction of Motion Artifacts in Magnetic-Resonance
Images Using an Entropy Focus Criterion,
MedImg(16), No. 6, December 1997, pp. 903-910.
IEEE Top Reference.
9803
BibRef
Weerasinghe, C.,
Yan, H.,
An Improved Algorithm for Rotational Motion Artifact Suppression
in MRI,
MedImg(17), No. 2, April 1998, pp. 310-317.
IEEE Top Reference.
9808
BibRef
Weerasinghe, C.,
Yan, H.,
Correction of Motion Artifacts in MRI Caused by Rotations at
Constant Angular Velocity,
SP(70), No. 2, October 1998, pp. 103-114.
9812
BibRef
Deichmann, R.,
Wiesmann, F.,
Hillenbrand, C.,
Hahn, D.,
Haase, A.,
Contrast enhancement and artifact reduction in magnetization-prepared
MR angiography,
IJIST(10), No. 3, 1999, pp. 266-272.
BibRef
9900
Nowak, R.D.,
Wavelet-Based Rician Noise Removal for Magnetic Resonance Imaging,
IP(8), No. 10, October 1999, pp. 1408-1419.
WWW Version.
BibRef
9910
Ahn, C.B.,
Song, Y.C.,
Park, D.J.,
Adaptive template filtering for signal-to-noise ratio enhancement in
magnetic resonance imaging,
MedImg(18), No. 6, June 1999, pp. 549-556.
IEEE Top Reference.
0110
BibRef
Weaver, J.B.[John B.],
Applications of monotonic noise reduction algorithms in fMRI, phase
estimation, and contrast enhancement,
IJIST(10), No. 2, 1999, pp. 177-185.
BibRef
9900
Weerasinghe, C.[Chaminda],
Ji, L.[Lilian],
Yan, H.[Hong],
A new method for ROI extraction from motion affected MR images based on
suppression of artifacts in the image background,
SP(80), No. 5, May 2000, pp. 867-88.
0005
BibRef
Kao, Y.H.[Yi-Hsuan],
MacFall, J.R.,
Correction of MR k-space data corrupted by spike noise,
MedImg(19), No. 7, July 2000, pp. 671-680.
IEEE Top Reference.
0110
BibRef
Glowinski, A.,
Adam, G.,
Bucker, A.,
van Vaals, J.,
Gunther, R.W.,
A perspective on needle artifacts in MRI: an electromagnetic model for
experimentally separating susceptibility effects,
MedImg(19), No. 12, December 2000, pp. 1248-1252.
IEEE Top Reference.
0110
BibRef
Bishop, J.,
Samani, A.,
Sciarretta, J.,
Luginbuhl, C.,
Plewes, D.B.,
A signal/noise analysis of quasi-static MR elastography,
MedImg(20), No. 11, November 2001, pp. 1183-1187.
IEEE Top Reference.
0111
BibRef
Xu, Z.H.[Zhi-Hua],
Chan, A.K.,
Encoding with frames in MRI and analysis of the signal-to-noise ratio,
MedImg(21), No. 4, April 2002, pp. 332-342.
IEEE Top Reference.
0206
BibRef
Archibald, R.,
Gelb, A.,
A method to reduce the Gibbs ringing artifact in MRI scans while
keeping tissue boundary integrity,
MedImg(21), No. 4, April 2002, pp. 305-319.
IEEE Top Reference.
0206
BibRef
Archibald, R.,
Hu, J.,
Gelb, A.,
Farin, G.,
Improving the Accuracy of Volumetric Segmentation Using Pre-Processing
Boundary Detection and Image Reconstruction,
IP(13), No. 4, April 2004, pp. 459-466.
WWW Version.
0404
BibRef
Bao, P.,
Zhang, L.[Lei],
Noise reduction for magnetic resonance images via adaptive multiscale
products thresholding,
MedImg(22), No. 9, September 2003, pp. 1089-1099.
IEEE Abstract. IEEE Top Reference.
0309
BibRef
Lysaker, M.,
Lundervold, A.,
Tai, X.C.[Xue-Cheng],
Noise removal using fourth-order partial differential equation with
applications to medical magnetic resonance images in space and time,
IP(12), No. 12, December 2003, pp. 1579-1590.
WWW Version.
0402
BibRef
Winkelmann, S.,
Schaeffter, T.,
Eggers, H.,
Doessel, O.,
SNR Enhancement in Radial SSFP Imaging Using Partial k-Space Averaging,
MedImg(24), No. 2, February 2005, pp. 254-262.
IEEE Abstract. IEEE Top Reference.
0501SSFP: steady-state free precessing. MRI sequences.
BibRef
Winkelmann, S.,
Schaeffter, T.,
Koehler, T.,
Eggers, H.,
Doessel, O.,
An Optimal Radial Profile Order Based on the Golden Ratio for
Time-Resolved MRI,
MedImg(26), No. 1, January 2007, pp. 68-76.
WWW Version.
0701
BibRef
Madabhushi, A.[Anant],
Udupa, J.K.[Jayaram K.],
Interplay Between Intensity Standardization and Inhomogeneity
Correction in MR Image Processing,
MedImg(24), No. 5, May 2005, pp. 561-576.
IEEE Abstract. IEEE Top Reference.
0505
BibRef
Madabhushi, A.[Anant],
Udupa, J.K.[Jayaram K.],
Souza, A.[Andre],
Generalized scale: Theory, algorithms, and application to image
inhomogeneity correction,
CVIU(101), No. 2, February 2005, pp. 100-121.
WWW Version.
0512
BibRef
Ahmed, O.A.,
New Denoising Scheme for Magnetic Resonance Spectroscopy Signals,
MedImg(24), No. 6, June 2005, pp. 809-816.
IEEE Abstract. IEEE Top Reference.
0506
BibRef
Chang, Z.,
Xiang, Q.S.,
Nonlinear Phase Correction With an Extended Statistical Algorithm,
MedImg(24), No. 6, June 2005, pp. 791-798.
IEEE Abstract. IEEE Top Reference.
0506MRI phase correction.
BibRef
Luo, J.,
Zhu, Y.,
Clarysse, P.,
Magnin, I.,
Correction of Bias Field in MR Images Using Singularity Function
Analysis,
MedImg(24), No. 8, August 2005, pp. 1067-1085.
WWW Version.
0508
BibRef
Lin, W.,
Wehrli, F.W.,
Song, H.K.,
Correcting Bulk In-Plane Motion Artifacts in MRI Using the Point Spread
Function,
MedImg(24), No. 9, September 2005, pp. 1170-1176.
WWW Version.
0509
BibRef
Pauchard, Y.,
Smith, M.R.,
Mintchev, M.P.,
Improving Geometric Accuracy in the Presence of Susceptibility
Difference Artifacts Produced by Metallic Implants in Magnetic
Resonance Imaging,
MedImg(24), No. 10, October 2005, pp. 1387-1399.
WWW Version.
0510
BibRef
Kobashi, S.[Syoji],
Kondo, K.[Katsuya],
Hata, Y.[Yutaka],
Target image enhancement using representative line in MR
cholangiography images,
IJIST(14), No. 3, 2004, pp. 122-130.
WWW Version.
0408
BibRef
Ibrahim, T.S.,
Ultrahigh-Field MRI Whole-Slice and Localized RF Field Excitations
Using the Same RF Transmit Array,
MedImg(25), No. 10, October 2006, pp. 1341-1347.
WWW Version.
0609
BibRef
Khalidov, I.,
van de Ville, D.,
Jacob, M.,
Lazeyras, F.,
Unser, M.,
BSLIM: Spectral Localization by Imaging With Explicit B{0} Field
Inhomogeneity Compensation,
MedImg(26), No. 7, July 2007, pp. 990-1000.
WWW Version.
0707Magnetic resonance spectroscopy imaging (MRSI)
BibRef
Garcia-Sebastian, M.[Maite],
Fernandez, E.[Elsa],
Grana, M.[Manuel],
Torrealdea, F.J.[Francisco J.],
A parametric gradient descent MRI intensity inhomogeneity correction
algorithm,
PRL(28), No. 13, 1 October 2007, pp. 1657-1666.
WWW Version.
0709MRI; Intensity inhomogeneity correction; Parametric methods
BibRef
Awate, S.P.,
Whitaker, R.T.,
Feature-Preserving MRI Denoising: A Nonparametric Empirical Bayes
Approach,
MedImg(26), No. 9, September 2007, pp. 1242-1255.
WWW Version.
0710
BibRef
Hamarneh, G.,
Hradsky, J.,
Bilateral Filtering of Diffusion Tensor Magnetic Resonance Images,
IP(16), No. 10, October 2007, pp. 2463-2475.
WWW Version.
0711
BibRef
Gilbert, G.,
Simard, D.,
Beaudoin, G.,
Impact of an Improved Combination of Signals From Array Coils in
Diffusion Tensor Imaging,
MedImg(26), No. 11, November 2007, pp. 1428-1436.
WWW Version.
0709
BibRef
Latt, J.,
Nilsson, M.,
Malmborg, C.,
Rosquist, H.,
Wirestam, R.,
Stahlberg, F.,
Topgaard, D.,
Brockstedt, S.,
Accuracy of q-Space Related Parameters in MRI:
Simulations and Phantom Measurements,
MedImg(26), No. 11, November 2007, pp. 1437-1447.
WWW Version.
0709
BibRef
Matter, N.I.,
Chronik, B.,
Pauly, J.M.,
Macovski, A.,
Conolly, S.M.,
Scott, G.C.,
Noise Performance of a Precision Pulsed Electromagnet Power Supply for
Magnetic Resonance Imaging,
MedImg(27), No. 1, January 2008, pp. 75-86.
WWW Version.
0712
BibRef
Coupe, P.,
Yger, P.,
Prima, S.,
Hellier, P.,
Kervrann, C.,
Barillot, C.,
An Optimized Blockwise Nonlocal Means Denoising Filter for 3-D Magnetic
Resonance Images,
MedImg(27), No. 4, April 2008, pp. 425-441.
WWW Version.
0804
BibRef
Ardizzone, E.[Edoardo],
Pirrone, R.[Roberto],
La Bua, S.[Salvatore],
Gambino, O.[Orazio],
Volumetric Bias Correction,
MIRAGE07(525-533).
WWW Version.
0703Bias correction in MRI data.
BibRef
Belaroussi, B.,
Benoit-Cattin, H.,
Odet, C.,
CASTI: Correction of Susceptibility Artifact in MR Images using MRI
Simulation,
ICIP06(897-900).
0610
WWW Version.
BibRef
Zagorodnov, V.,
Hansen, M.F.,
Performance Evaluation of Parametric Bias Field Correction,
ICIP05(III: 732-735).
WWW Version.
0512MRI enhancement.
BibRef
Thacker, N.A.,
Pokric, M.,
Williamson, D.C.,
Noise Filtering and Testing Illustrated Using a Multi-Dimensional
Partial Volume Model of MR Data,
BMVC04(xx-yy).
HTML Version.
0508
BibRef
Blezek, D.J.[Daniel J.],
Dixon, W.T.[W. Thomas],
Dhawale, P.J.[Paritosh J.],
Single Image Phase-Based MRI Fat Suppression Expectation Maximization
Algorithm,
CVPR05(II: 540-546).
WWW Version.
0507
BibRef
Gispert, J.D.,
Reig, S.,
Pascau, J.,
Lazaro, R.M.,
Vaquero, J.J.,
Desco, M.,
Inhomogeneity correction of magnetic resonance images by minimization
of intensity overlapping,
ICIP03(II: 847-850).
IEEE Abstract. IEEE Top Reference.
0312
BibRef
Aggarwal, N.,
Bresler, Y.,
Optimal sampling in parallel magnetic resonance imaging,
ICIP03(II: 839-842).
IEEE Abstract. IEEE Top Reference.
0312
BibRef
Fadili, M.,
Bullmore, E.,
Brett, M.,
Wavelet Methods for Characterising Mono- and Poly-fractal Noise
Structures in Shortish Time Series: an Application to Functional MRI,
ICIP01(II: 225-228).
IEEE Abstract. IEEE Top Reference.
0108
BibRef
Jammal, G.[Ghada],
Bijaoui, A.[Albert],
Denoising and Deconvolution in Nuclear Medicine,
ICIP99(III:896-900).
IEEE Abstract. IEEE Top Reference.
BibRef
9900
Garza-Jinich, M.,
Yanez, O.,
Medina, V.,
Meer, P.,
Automatic correction of bias field in magnetic resonance images,
CIAP99(752-756).
WWW Version.
9909
BibRef
Kadah, Y.M.,
Hu, X.P.[Xiao-Ping],
Automatic suppression of spatially variant translational motion
artifacts in magnetic resonance imaging,
ICIP98(I: 24-28).
WWW Version.
9810
BibRef
Tseng, Y.H.[Yen-Hao],
Hwang, J.N.[Jenq-Neng],
Yuan, C.[Chun],
Motion artifact correction of MRI via iterative inverse problem solving,
ICIP94(I: 871-875).
WWW Version.
9411
BibRef
Smith, M.,
Zeng, J.,
Crawley, A.,
A moving target evaluating algorithms for removing MRI motion artifacts,
ICIP94(III: 45-48).
WWW Version.
9411
BibRef
Bajla, I.,
Marušiak, M.,
Šrámek, M.,
Anisotropic filtering of MRI data based upon image gradient histogram,
CAIP93(90-97).
WWW Version.
9309
BibRef
Chapter on Medical Applications, CAT, MRI, Ultrasound, Heart Models, Brain Models continues in
MRI, Surveys, Overviews, Evaluations .