Zoroofi, R.A.,
Sato, Y.,
Tamura, S.,
Naito, H.,
MRI artifact cancellation due to rigid motion in the imaging plane,
MedImg(15), No. 6, December 1996, pp. 768-784.
IEEE Top Reference.
0203
BibRef
Atkinson, D.,
Hill, D.L.G.,
Stoyle, P.N.R.,
Summers, P.E.,
Keevil, S.F.,
Automatic Correction of Motion Artifacts in Magnetic-Resonance
Images Using an Entropy Focus Criterion,
MedImg(16), No. 6, December 1997, pp. 903-910.
IEEE Top Reference.
9803
BibRef
Bajla, I.,
Hollander, I.,
Nonlinear Filtering of Magnetic Resonance Tomograms by
Geometry Driven Diffusion,
MVA(10), No. 5-6, April 1998, pp. 243-255.
HTML Version.
9805
BibRef
Bajla, I.,
Holländer, I.,
Locally adaptive conductance in geometry-driven-diffusion filtering of
magnetic resonance tomograms,
VISP(147), No. 3, 2000, pp. 271-282.
0008
BibRef
Bajla, I.[Ivan],
Holländer, I.[Igor],
Geometry-driven-diffusion filtering of magnetic resonance images using
model-based conductance,
MVA(12), No. 5, 2001, pp. 223-237.
HTML Version.
0103
BibRef
Weerasinghe, C.,
Yan, H.,
An Improved Algorithm for Rotational Motion Artifact Suppression
in MRI,
MedImg(17), No. 2, April 1998, pp. 310-317.
IEEE Top Reference.
9808
BibRef
Weerasinghe, C.,
Yan, H.,
Correction of Motion Artifacts in MRI Caused by Rotations at
Constant Angular Velocity,
SP(70), No. 2, October 1998, pp. 103-114.
9812
BibRef
Deichmann, R.,
Wiesmann, F.,
Hillenbrand, C.,
Hahn, D.,
Haase, A.,
Contrast enhancement and artifact reduction in magnetization-prepared
MR angiography,
IJIST(10), No. 3, 1999, pp. 266-272.
BibRef
9900
Nowak, R.D.,
Wavelet-Based Rician Noise Removal for Magnetic Resonance Imaging,
IP(8), No. 10, October 1999, pp. 1408-1419.
IEEE DOI Link
BibRef
9910
Ahn, C.B.,
Song, Y.C.,
Park, D.J.,
Adaptive template filtering for signal-to-noise ratio enhancement in
magnetic resonance imaging,
MedImg(18), No. 6, June 1999, pp. 549-556.
IEEE Top Reference.
0110
BibRef
Weaver, J.B.[John B.],
Applications of monotonic noise reduction algorithms in fMRI, phase
estimation, and contrast enhancement,
IJIST(10), No. 2, 1999, pp. 177-185.
BibRef
9900
Bakir, T.,
Reeves, S.J.,
A filter design method for minimizing ringing in a region of interest
in MR spectroscopic images,
MedImg(19), No. 6, June 2000, pp. 585-600.
IEEE Top Reference.
0110
BibRef
Weerasinghe, C.[Chaminda],
Ji, L.[Lilian],
Yan, H.[Hong],
A new method for ROI extraction from motion affected MR images based on
suppression of artifacts in the image background,
SP(80), No. 5, May 2000, pp. 867-88.
0005
BibRef
Kao, Y.H.[Yi-Hsuan],
MacFall, J.R.,
Correction of MR k-space data corrupted by spike noise,
MedImg(19), No. 7, July 2000, pp. 671-680.
IEEE Top Reference.
0110
BibRef
Glowinski, A.,
Adam, G.,
Bucker, A.,
van Vaals, J.,
Gunther, R.W.,
A perspective on needle artifacts in MRI: an electromagnetic model for
experimentally separating susceptibility effects,
MedImg(19), No. 12, December 2000, pp. 1248-1252.
IEEE Top Reference.
0110
BibRef
Bishop, J.,
Samani, A.,
Sciarretta, J.,
Luginbuhl, C.,
Plewes, D.B.,
A signal/noise analysis of quasi-static MR elastography,
MedImg(20), No. 11, November 2001, pp. 1183-1187.
IEEE Top Reference.
0111
BibRef
Xu, Z.H.[Zhi-Hua],
Chan, A.K.,
Encoding with frames in MRI and analysis of the signal-to-noise ratio,
MedImg(21), No. 4, April 2002, pp. 332-342.
IEEE Top Reference.
0206
BibRef
Archibald, R.,
Gelb, A.,
A method to reduce the Gibbs ringing artifact in MRI scans while
keeping tissue boundary integrity,
MedImg(21), No. 4, April 2002, pp. 305-319.
IEEE Top Reference.
0206
BibRef
Archibald, R.,
Hu, J.,
Gelb, A.,
Farin, G.,
Improving the Accuracy of Volumetric Segmentation Using Pre-Processing
Boundary Detection and Image Reconstruction,
IP(13), No. 4, April 2004, pp. 459-466.
IEEE DOI Link
0404
BibRef
Bao, P.,
Zhang, L.[Lei],
Noise reduction for magnetic resonance images via adaptive multiscale
products thresholding,
MedImg(22), No. 9, September 2003, pp. 1089-1099.
IEEE Abstract.
0309
BibRef
Lysaker, M.,
Lundervold, A.,
Tai, X.C.[Xue-Cheng],
Noise removal using fourth-order partial differential equation with
applications to medical magnetic resonance images in space and time,
IP(12), No. 12, December 2003, pp. 1579-1590.
IEEE DOI Link
0402
BibRef
Winkelmann, S.,
Schaeffter, T.,
Eggers, H.,
Doessel, O.,
SNR Enhancement in Radial SSFP Imaging Using Partial k-Space Averaging,
MedImg(24), No. 2, February 2005, pp. 254-262.
IEEE Abstract.
0501
SSFP: steady-state free precessing. MRI sequences.
BibRef
Winkelmann, S.,
Schaeffter, T.,
Koehler, T.,
Eggers, H.,
Doessel, O.,
An Optimal Radial Profile Order Based on the Golden Ratio for
Time-Resolved MRI,
MedImg(26), No. 1, January 2007, pp. 68-76.
IEEE DOI Link
0701
BibRef
Madabhushi, A.[Anant],
Udupa, J.K.[Jayaram K.],
Interplay Between Intensity Standardization and Inhomogeneity
Correction in MR Image Processing,
MedImg(24), No. 5, May 2005, pp. 561-576.
IEEE Abstract.
0505
BibRef
Madabhushi, A.[Anant],
Udupa, J.K.[Jayaram K.],
Souza, A.[Andre],
Generalized scale: Theory, algorithms, and application to image
inhomogeneity correction,
CVIU(101), No. 2, February 2005, pp. 100-121.
WWW Version.
0512
BibRef
Ahmed, O.A.,
New Denoising Scheme for Magnetic Resonance Spectroscopy Signals,
MedImg(24), No. 6, June 2005, pp. 809-816.
IEEE Abstract.
0506
BibRef
Chang, Z.,
Xiang, Q.S.,
Nonlinear Phase Correction With an Extended Statistical Algorithm,
MedImg(24), No. 6, June 2005, pp. 791-798.
IEEE Abstract.
0506
MRI phase correction.
BibRef
Luo, J.,
Zhu, Y.,
Clarysse, P.,
Magnin, I.,
Correction of Bias Field in MR Images Using Singularity Function
Analysis,
MedImg(24), No. 8, August 2005, pp. 1067-1085.
IEEE DOI Link
0508
BibRef
Lin, W.,
Wehrli, F.W.,
Song, H.K.,
Correcting Bulk In-Plane Motion Artifacts in MRI Using the Point Spread
Function,
MedImg(24), No. 9, September 2005, pp. 1170-1176.
IEEE DOI Link
0509
BibRef
Pauchard, Y.,
Smith, M.R.,
Mintchev, M.P.,
Improving Geometric Accuracy in the Presence of Susceptibility
Difference Artifacts Produced by Metallic Implants in Magnetic
Resonance Imaging,
MedImg(24), No. 10, October 2005, pp. 1387-1399.
IEEE DOI Link
0510
BibRef
Kobashi, S.[Syoji],
Kondo, K.[Katsuya],
Hata, Y.[Yutaka],
Target image enhancement using representative line in MR
cholangiography images,
IJIST(14), No. 3, 2004, pp. 122-130.
WWW Version.
0408
BibRef
Ibrahim, T.S.,
Ultrahigh-Field MRI Whole-Slice and Localized RF Field Excitations
Using the Same RF Transmit Array,
MedImg(25), No. 10, October 2006, pp. 1341-1347.
IEEE DOI Link
0609
BibRef
Khalidov, I.,
van de Ville, D.,
Jacob, M.,
Lazeyras, F.,
Unser, M.,
BSLIM: Spectral Localization by Imaging With Explicit B{0} Field
Inhomogeneity Compensation,
MedImg(26), No. 7, July 2007, pp. 990-1000.
IEEE DOI Link
0707
Magnetic resonance spectroscopy imaging (MRSI)
BibRef
Garcia-Sebastian, M.[Maite],
Fernandez, E.[Elsa],
Grana, M.[Manuel],
Torrealdea, F.J.[Francisco J.],
A parametric gradient descent MRI intensity inhomogeneity correction
algorithm,
PRL(28), No. 13, 1 October 2007, pp. 1657-1666.
WWW Version.
0709
MRI; Intensity inhomogeneity correction; Parametric methods
BibRef
Awate, S.P.,
Whitaker, R.T.,
Feature-Preserving MRI Denoising: A Nonparametric Empirical Bayes
Approach,
MedImg(26), No. 9, September 2007, pp. 1242-1255.
IEEE DOI Link
0710
BibRef
Hamarneh, G.,
Hradsky, J.,
Bilateral Filtering of Diffusion Tensor Magnetic Resonance Images,
IP(16), No. 10, October 2007, pp. 2463-2475.
IEEE DOI Link
0711
BibRef
Gilbert, G.,
Simard, D.,
Beaudoin, G.,
Impact of an Improved Combination of Signals From Array Coils in
Diffusion Tensor Imaging,
MedImg(26), No. 11, November 2007, pp. 1428-1436.
IEEE DOI Link
0709
BibRef
Latt, J.,
Nilsson, M.,
Malmborg, C.,
Rosquist, H.,
Wirestam, R.,
Stahlberg, F.,
Topgaard, D.,
Brockstedt, S.,
Accuracy of q-Space Related Parameters in MRI:
Simulations and Phantom Measurements,
MedImg(26), No. 11, November 2007, pp. 1437-1447.
IEEE DOI Link
0709
BibRef
Matter, N.I.,
Chronik, B.,
Pauly, J.M.,
Macovski, A.,
Conolly, S.M.,
Scott, G.C.,
Noise Performance of a Precision Pulsed Electromagnet Power Supply for
Magnetic Resonance Imaging,
MedImg(27), No. 1, January 2008, pp. 75-86.
IEEE DOI Link
0712
BibRef
Sumbul, U.,
Santos, J.M.,
Pauly, J.M.,
Improved Time Series Reconstruction for Dynamic Magnetic Resonance
Imaging,
MedImg(28), No. 7, July 2009, pp. 1093-1104.
IEEE DOI Link
0906
BibRef
Sumbul, U.,
Santos, J.M.,
Pauly, J.M.,
A Practical Acceleration Algorithm for Real-Time Imaging,
MedImg(28), No. 12, December 2009, pp. 2042-2051.
IEEE DOI Link
0912
BibRef
Cukur, T.,
Santos, J.M.,
Pauly, J.M.,
Nishimura, D.G.,
Variable-Density Parallel Imaging With Partially Localized Coil
Sensitivities,
MedImg(29), No. 5, May 2010, pp. 1173-1181.
IEEE DOI Link
1006
BibRef
Coupe, P.,
Yger, P.,
Prima, S.,
Hellier, P.,
Kervrann, C.,
Barillot, C.,
An Optimized Blockwise Nonlocal Means Denoising Filter for 3-D Magnetic
Resonance Images,
MedImg(27), No. 4, April 2008, pp. 425-441.
IEEE DOI Link
0804
BibRef
Coupe, P.,
Hellier, P.,
Kervrann, C.,
Barillot, C.,
Nonlocal Means-Based Speckle Filtering for Ultrasound Images,
IP(18), No. 10, October 2009, pp. 2221-2229.
IEEE DOI Link
0909
BibRef
Aja-Fernandez, S.,
Alberola-Lopez, C.,
Westin, C.F.,
Noise and Signal Estimation in Magnitude MRI and Rician Distributed
Images: A LMMSE Approach,
IP(17), No. 8, August 2008, pp. 1383-1398.
IEEE DOI Link
0808
BibRef
Aja-Fernandez, S.[Santiago],
Niethammer, M.,
Kubicki, M.,
Shenton, M.E.,
Westin, C.F.,
Restoration of DWI Data Using a Rician LMMSE Estimator,
MedImg(27), No. 10, October 2008, pp. 1389-1403.
IEEE DOI Link
0810
Diffusion weighted magnetic resonance imaging.
BibRef
Yuan, Y.,
Zhu, H.,
Ibrahim, J.G.,
Lin, W.,
Peterson, B.G.,
A Note on the Validity of Statistical Bootstrapping for Estimating the
Uncertainty of Tensor Parameters in Diffusion Tensor Images,
MedImg(27), No. 10, October 2008, pp. 1506-1514.
IEEE DOI Link
0810
BibRef
He, L.,
Greenshields, I.R.,
A Nonlocal Maximum Likelihood Estimation Method for Rician Noise
Reduction in MR Images,
MedImg(28), No. 2, February 2009, pp. 165-172.
IEEE DOI Link
0902
BibRef
Knopp, T.,
Eggers, H.,
Dahnke, H.,
Prestin, J.,
Senegas, J.,
Iterative Off-Resonance and Signal Decay Estimation and Correction for
Multi-Echo MRI,
MedImg(28), No. 3, March 2009, pp. 394-404.
IEEE DOI Link
0903
BibRef
Nguyen, H.M.,
Sutton, B.P.,
Morrison, Jr., R.L.,
Do, M.N.,
Joint Estimation and Correction of Geometric Distortions for EPI
Functional MRI Using Harmonic Retrieval,
MedImg(28), No. 3, March 2009, pp. 423-434.
IEEE DOI Link
0903
BibRef
Chou, H.F.[Hsiao-Fang],
Younes, L.[Laurent],
Smoothing Directional Vector Fields Using Dual Norms,
SIIMS(2), No. 1, 2009, pp. 41-63.
diffusion tensor imaging; magnetic resonance imaging; noise removal;
tensor; diffusion tensor interpolation
WWW Version.
WWW Version.
BibRef
0900
Krissian, K.,
Aja-Fernandez, S.,
Noise-Driven Anisotropic Diffusion Filtering of MRI,
IP(18), No. 10, October 2009, pp. 2265-2274.
IEEE DOI Link
0909
See also Flux-based anisotropic diffusion applied to enhancement of 3-D angiogram.
BibRef
Maitra, R.,
Faden, D.,
Noise Estimation in Magnitude MR Datasets,
MedImg(28), No. 10, October 2009, pp. 1615-1622.
IEEE DOI Link
0910
BibRef
Hsu, Y.C.,
Hsu, C.H.,
Tseng, W.Y.I.,
Correction for Susceptibility-Induced Distortion in Echo-Planar Imaging
Using Field Maps and Model-Based Point Spread Function,
MedImg(28), No. 11, November 2009, pp. 1850-1857.
IEEE DOI Link
0911
BibRef
Gur, Y.[Yaniv],
Pasternak, O.[Ofer],
Sochen, N.A.[Nir A.],
Fast GL(n)-Invariant Framework for Tensors Regularization,
IJCV(85), No. 3, December 2009, pp. xx-yy.
Springer DOI Link
0911
BibRef
Gur, Y.[Yaniv],
Sochen, N.A.[Nir A.],
Fast Invariant Riemannian DT-MRI Regularization,
MMBIA07(1-7).
IEEE DOI Link
0710
BibRef
Elen, A.,
Hermans, J.,
Ganame, J.,
Loeckx, D.,
Bogaert, J.,
Maes, F.,
Suetens, P.,
Automatic 3-D Breath-Hold Related Motion Correction of Dynamic
Multislice MRI,
MedImg(29), No. 3, March 2010, pp. 868-878.
IEEE DOI Link
1003
BibRef
Poot, D.H.J.,
den Dekker, A.J.,
Achten, E.,
Verhoye, M.,
Sijbers, J.[Jan],
Optimal Experimental Design for Diffusion Kurtosis Imaging,
MedImg(29), No. 3, March 2010, pp. 819-829.
IEEE DOI Link
1003
MRI model for non-Gaussian diffusion in tissue.
BibRef
Jung, H.[Hong],
Ye, J.C.[Jong Chul],
Motion estimated and compensated compressed sensing dynamic magnetic
resonance imaging: What we can learn from video compression techniques,
IJIST(20), No. 2, June 2010, pp. 81-98.
WWW Version.
1006
BibRef
Qi, L.Q.[Li-Qun],
Yu, G.H.[Gao-Hang],
Wu, E.X.[Ed X.],
Higher Order Positive Semidefinite Diffusion Tensor Imaging,
SIIMS(3), No. 3, 2010, pp. 416-433.
WWW Version.
WWW Version. positive semidefinite diffusion tensor; apparent diffusion
coefficient; Z-eigenvalue; convex optimization problem; invariants
BibRef
1000
Khademi, A.,
Venetsanopoulos, A.,
Moody, A.R.,
Image Enhancement and Noise Suppression for FLAIR MRIs With White
Matter Lesions,
SPLetters(17), No. 12, December 2010, pp. 989-992.
IEEE DOI Link
1011
BibRef
Dowson, N.[Nicholas],
Salvado, O.[Olivier],
Hashed Nonlocal Means for Rapid Image Filtering,
PAMI(33), No. 3, March 2011, pp. 485-499.
IEEE DOI Link
1102
3-D data noise filtering. Retain structure.
BibRef
Ozcan, A.[Aydogan],
Minimization of Imaging Gradient Effects in Diffusion Tensor Imaging,
MedImg(30), No. 3, March 2011, pp. 642-654.
IEEE DOI Link
1103
BibRef
Knopp, T.,
Biederer, S.,
Sattel, T.F.,
Erbe, M.,
Buzug, T.M.,
Prediction of the Spatial Resolution of Magnetic Particle Imaging Using
the Modulation Transfer Function of the Imaging Process,
MedImg(30), No. 6, June 2011, pp. 1284-1292.
IEEE DOI Link
1101
BibRef
Puy, G.,
Vandergheynst, P.,
Wiaux, Y.,
On Variable Density Compressive Sampling,
SPLetters(18), No. 10, October 2011, pp. 595-598.
IEEE DOI Link
1109
BibRef
Getreuer, P.[Pascal],
Contour Stencils: Total Variation along Curves for Adaptive Image
Interpolation,
SIIMS(4), No. 3, 2011, pp. 954-979.
WWW Version.
1110
BibRef
Getreuer, P.[Pascal],
Tong, M.[Melissa],
Vese, L.A.[Luminita A.],
A Variational Model for the Restoration of MR Images Corrupted by Blur
and Rician Noise,
ISVC11(I: 686-698).
Springer DOI Link
1109
BibRef
Duits, R.[Remco],
Haije, T.C.J.D.[Tom C. J. Dela],
Ghosh, A.[Arpan],
Creusen, E.[Eric],
Vilanova, A.[Anna],
ter Haar Romeny, B.M.[Bart M.],
Fiber Enhancement in Diffusion-Weighted MRI,
SSVM11(1-13).
Springer DOI Link
1201
BibRef
Creusen, E.J.[Eric J.],
Duits, R.[Remco],
Haije, T.C.J.D.[Tom C. J. Dela],
Numerical Schemes for Linear and Non-linear Enhancement of DW-MRI,
SSVM11(14-25).
Springer DOI Link
1201
BibRef
Mohan, J,
Krishnaveni, V,
Guo, Y.H.[Yan-Hui],
A Neutrosophic approach of MRI denoising,
ICIIP11(1-6).
IEEE DOI Link
1112
BibRef
Soto, M.E.[Miguel E.],
Pezoa, J.E.[Jorge E.],
Torres, S.N.[Sergio N.],
Thermal Noise Estimation and Removal in MRI:
A Noise Cancellation Approach,
CIARP11(47-54).
Springer DOI Link
1111
BibRef
Wei, S.M.[Si-Ming],
Hua, J.[Jing],
Bu, J.J.[Jia-Jun],
Chen, C.[Chun],
Yu, Y.Z.[Yi-Zhou],
Bayesian regularization of diffusion tensor images using hierarchical
MCMC and loopy belief propagation,
ICIP10(65-68).
IEEE DOI Link
1009
BibRef
Chaari, L.[Lotfi],
Benazza-Benyahia, A.[Amel],
Pesquet, J.C.[Jean-Christophe],
Ciuciu, P.[Philippe],
Wavelet-based parallel MRI regularization using bivariate sparsity
promoting priors,
ICIP09(1725-1728).
IEEE DOI Link
0911
BibRef
Rajan, J.,
Jeurissen, B.,
Sijbers, J.,
Kannan, K.,
Denoising Magnetic Resonance Images Using Fourth Order Complex
Diffusion,
IMVIP09(123-127).
IEEE DOI Link
0909
BibRef
Tan, L.[Lina],
Shi, L.W.[Liang-Wu],
Multiwavelet-Based Estimation for Improving Magnetic Resonance Images,
CISP09(1-5).
IEEE DOI Link
0910
BibRef
Su, H.R.[Hong-Ren],
Lee, T.Y.[Tung-Ying],
Lai, S.H.[Shang-Hong],
Chang, T.C.[Ti-Chiun],
MRI motion artifact correction based on spectral extrapolation with
generalized series,
ICIP10(1133-1136).
IEEE DOI Link
1009
BibRef
Earlier: A2, A1, A3, A4:
Compensation of motion artifacts in MRI via graph-based optimization,
CVPR09(2192-2199).
IEEE DOI Link
0906
BibRef
Ardizzone, E.[Edoardo],
Pirrone, R.[Roberto],
La Bua, S.[Salvatore],
Gambino, O.[Orazio],
Volumetric Bias Correction,
MIRAGE07(525-533).
Springer DOI Link
0703
Bias correction in MRI data.
BibRef
Belaroussi, B.,
Benoit-Cattin, H.,
Odet, C.,
CASTI: Correction of Susceptibility Artifact in MR Images using MRI
Simulation,
ICIP06(897-900).
IEEE DOI Link
0610
BibRef
Zagorodnov, V.,
Hansen, M.F.,
Performance Evaluation of Parametric Bias Field Correction,
ICIP05(III: 732-735).
IEEE DOI Link
0512
MRI enhancement.
BibRef
Thacker, N.A.,
Pokric, M.,
Williamson, D.C.,
Noise Filtering and Testing Illustrated Using a Multi-Dimensional
Partial Volume Model of MR Data,
BMVC04(xx-yy).
HTML Version.
0508
BibRef
Blezek, D.J.[Daniel J.],
Dixon, W.T.[W. Thomas],
Dhawale, P.J.[Paritosh J.],
Single Image Phase-Based MRI Fat Suppression Expectation Maximization
Algorithm,
CVPR05(II: 540-546).
IEEE DOI Link
0507
BibRef
Gispert, J.D.,
Reig, S.,
Pascau, J.,
Lazaro, R.M.,
Vaquero, J.J.,
Desco, M.,
Inhomogeneity correction of magnetic resonance images by minimization
of intensity overlapping,
ICIP03(II: 847-850).
IEEE Abstract.
0312
BibRef
Aggarwal, N.,
Bresler, Y.,
Optimal sampling in parallel magnetic resonance imaging,
ICIP03(II: 839-842).
IEEE Abstract.
0312
BibRef
Fadili, M.,
Bullmore, E.,
Brett, M.,
Wavelet Methods for Characterising Mono- and Poly-fractal Noise
Structures in Shortish Time Series: an Application to Functional MRI,
ICIP01(II: 225-228).
IEEE Abstract.
0108
BibRef
Jiang, T.,
Kruggel, F.,
3D MR Image Restoration by Combining Local Genetic Algorithm with
Adaptive Pre-conditioning,
ICPR00(Vol III: 298-301).
IEEE DOI Link
IEEE DOI Link
0009
BibRef
Osman, N.F.,
Prince, J.L.,
On the Design of the Bandpass Filters in Harmonic Phase MRI,
ICIP00(Vol I: 625-628).
IEEE Abstract.
0008
BibRef
Jammal, G.[Ghada],
Bijaoui, A.[Albert],
Denoising and Deconvolution in Nuclear Medicine,
ICIP99(III:896-900).
IEEE Abstract.
BibRef
9900
Garza-Jinich, M.,
Yanez, O.,
Medina, V.,
Meer, P.,
Automatic correction of bias field in magnetic resonance images,
CIAP99(752-756).
IEEE DOI Link
9909
BibRef
Kadah, Y.M.,
Hu, X.P.[Xiao-Ping],
Automatic suppression of spatially variant translational motion
artifacts in magnetic resonance imaging,
ICIP98(I: 24-28).
IEEE DOI Link
9810
BibRef
Tseng, Y.H.[Yen-Hao],
Hwang, J.N.[Jenq-Neng],
Yuan, C.[Chun],
Motion artifact correction of MRI via iterative inverse problem solving,
ICIP94(I: 871-875).
IEEE DOI Link
9411
BibRef
Smith, M.,
Zeng, J.,
Crawley, A.,
A moving target evaluating algorithms for removing MRI motion artifacts,
ICIP94(III: 45-48).
IEEE DOI Link
9411
BibRef
Bajla, I.,
Marušiak, M.,
Šrámek, M.,
Anisotropic filtering of MRI data based upon image gradient histogram,
CAIP93(90-97).
Springer DOI Link
9309
BibRef
Chapter on Medical Applications, CAT, MRI, Ultrasound, Heart Models, Brain Models continues in