20.11.3 Magnetic Resonance Imaging, Registration, Alignment

Chapter Contents (Back)
MRI. Magnetic Resonance.

Sumanaweera, T.S., Glover, G.H., Binford, T.O., Adler, J.R.,
MR susceptibility misregistration correction,
MedImg(12), No. 2, June 1993, pp. 251-259.
IEEE Top Reference. BibRef 9306

Alexander, M.E.,
Fast hierarchical noniterative registration algorithm,
IJIST(10), No. 3, 1999, pp. 242-257. MRI DAta BibRef 9900

Buelow, H., Dooley, L., Wermser, D.,
Application of principal axes for registration of NMR image sequences,
PRL(21), No. 3, March 2000, pp. 329-336. 0004
BibRef

Krueger, S., Wolff, S., Schmitgen, A., Timinger, H., Bublat, M., Schaeffter, T., Nabavi, A.,
Fast and Accurate Automatic Registration for MR-Guided Procedures Using Active Microcoils,
MedImg(26), No. 3, March 2007, pp. 385-392.
IEEE DOI Link 0703
BibRef

Jager, F., Hornegger, J.,
Nonrigid Registration of Joint Histograms for Intensity Standardization in Magnetic Resonance Imaging,
MedImg(28), No. 1, January 2009, pp. 137-150.
IEEE DOI Link 0901
BibRef

Ingalhalikar, M.[Madhura], Yang, J.Z.[Jin-Zhong], Davatzikos, C.[Christos], Verma, R.[Ragini],
DTI-DROID: Diffusion tensor imaging-deformable registration using orientation and intensity descriptors,
IJIST(20), No. 2, June 2010, pp. 99-107.
WWW Version. 1006
BibRef

Mahapatra, D.[Dwarikanath], Sun, Y.[Ying],
Rigid Registration of Renal Perfusion Images Using a Neurobiology-Based Visual Saliency Model,
JIVP(2010), No. 2010, pp. xx-yy.
WWW Version. 1003
BibRef

Mahapatra, D.[Dwarikanath], Sun, Y.[Ying],
Integrating Segmentation Information for Improved MRF-Based Elastic Image Registration,
IP(21), No. 1, January 2012, pp. 170-183.
IEEE DOI Link 1112
BibRef

Geng, X., Ross, T.J., Gu, H., Shin, W., Zhan, W., Chao, Y.P., Lin, C.P., Schuff, N., Yang, Y.,
Diffeomorphic Image Registration of Diffusion MRI Using Spherical Harmonics,
MedImg(30), No. 3, March 2011, pp. 747-758.
IEEE DOI Link 1103
BibRef

Gooya, A.[Ali], Biros, G., Davatzikos, C.[Christos],
Deformable Registration of Glioma Images Using EM Algorithm and Diffusion Reaction Modeling,
MedImg(30), No. 2, February 2011, pp. 375-390.
IEEE DOI Link 1102
BibRef

Song, T.[Ting], Lee, V.S.[Vivian S.], Chen, Q.[Qun], Rusinek, H.[Henry], Laine, A.F.[Andrew F.],
An automated three-dimensional plus time registration framework for dynamic MR renography,
JVCIR(21), No. 1, January 2010, pp. 1-8.
Elsevier DOI Link
WWW Version. 1002
MR renography; Dynamic MR; 3D plus time registration; Dynamic contrast-enhanced imaging; Wavelet representation; Anisotropic diffusion; Fourier-based registration; Automated respiratory motion correction; WRFT BibRef

Liu, X., Abd-Elmoniem, K.Z., Stone, M., Murano, E.Z., Zhuo, J., Gullapalli, R.P., Prince, J.L.,
Incompressible Deformation Estimation Algorithm (IDEA) From Tagged MR Images,
MedImg(31), No. 2, February 2012, pp. 326-340.
IEEE DOI Link 1202
BibRef


Li, S.T.[Shu-Tao], Deng, S.C.[Sheng-Chu], Peng, J.L.[Jing-Lin],
A Comparison of Similarity Measures for 2D Rigid MR Image Registration Using Wavelet Transform,
PSIVT06(270-279).
Springer DOI Link 0612
BibRef

Singh, M.[Meghna], Mandal, M.K.[Mrinal K.], Basu, A.[Anup],
Confidence Measure for Temporal Registration of Recurrent Non-uniform Samples,
PReMI07(608-615).
Springer DOI Link 0712
BibRef
Earlier: A1, A3, A2:
Temporal Alignment of Time Varying MRI Datasets for High Resolution Medical Visualization,
ISVC06(I: 222-231).
Springer DOI Link 0611
BibRef

Singh, M., Thompson, R., Basu, A., Rieger, J., Mandal, M.K.,
Image Based Temporal Registration of MRI Data for Medical Visualization,
ICIP06(1169-1172).
IEEE DOI Link 0610
BibRef

Cheng, I.[Irene], Nilufar, S.[Sharmin], Basu, A.[Anup], Goebel, R.[Randy],
Shape Tracking and Registration for 4D Visualization of MRI and Structure,
ISVC06(I: 253-262).
Springer DOI Link 0611
BibRef

Sun, Y.[Ying], Jolly, M.P., Moura, J.M.F.,
Integrated registration of dynamic renal perfusion MR images,
ICIP04(III: 1923-1926).
IEEE DOI Link 0505
BibRef

Chapter on Medical Applications, CAT, MRI, Ultrasound, Heart Models, Brain Models continues in
MRI, Enhancement, Noise and Artifact Reduction .


Last update:May 16, 2012 at 20:31:07